Nimbus Water Systems Sierra Owner's Manual & Installation Manual

Reverse osmosis drinking water system
Hide thumbs Also See for Sierra:

Advertisement

REVERSE OSMOSIS DRINKING WATER SYSTEM
Owner's Manual &
Installation Guide
41840 McAlby Court, Suite A, CA, Murrieta 92562
800.451.9343 . Email: sierra@nimbuswater.com
1

Advertisement

Table of Contents
loading

Summary of Contents for Nimbus Water Systems Sierra

  • Page 1 REVERSE OSMOSIS DRINKING WATER SYSTEM Owner's Manual & Installation Guide 41840 McAlby Court, Suite A, CA, Murrieta 92562 800.451.9343 . Email: sierra@nimbuswater.com...
  • Page 2: About This System

    OWNERS MANUAL Maintenance Schedule The Nimbus Sierra reverse osmosis base unit must be serviced on a regular basis to maintain efficiency and to safeguard water quality. Each unit is equipped with a pre-filter, a membrane filter, and a post-filter. These cartridges work together to remove potential contaminants from your tap water and must be replaced at regular intervals.
  • Page 3: Maintenance

    Replacement of the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure the same efficiency and contaminant reduction performance. Use of non-Sierra replacement parts will invalidate the warranty as set forth in Section F of this Owner's Manual. Description Part No.
  • Page 4: System Performance

    OWNER'S MANUAL Performance Sheet System Performance Feed Water Requirements Daily production rate 42.8 L/d Feed water(3) Potable water (11.3 gpd) Feed pressure 275 kPa, (40psi) to 552kPa (80psi) Efficiency Rating(1) 8.8% Feed temperature 1°C (33°F) to 38°C (100°F) Recovery Rating (2) Total dissolved solids 2,000 mg/L maximum Chlorine...
  • Page 5: Arsenic Facts

    Have the treated water tested for arsenic to check if the system is working properly. The RO component of the Nimbus Sierra system must be replaced yearly to ensure the system will continue to remove pentavalent arsenic. The compo- nent identification and location where you can purchase this component are...
  • Page 6: System Warranty

    Disclaimers This Warranty applies only if the system is installed and used in compliance with the instructions enclosed with the system. The Warranty does not cover any non-standard Sierra parts. This Warranty does not cover the costs of repairs or adjustments to the unit that may be needed because of the use of improper parts, equipment or materials.
  • Page 7: Installation

    INSTALLATION Before You Begin The following instructions outline a typical water treatment system installation. Consult local plumbing codes and building regulations as they may pose different or additional requirements for the installation. The installer is responsible for ensuring that the installation is in compliance with all applicable state and local regulations.
  • Page 8 4' green 1/4" tubing 4' yellow 1/4" tubing The feed water connection assembly supplied with the Sierra system includes components which represent the most common under-sink plumbing connections currently in use within the United States. If these components do not match the type of connections installed at your location, contact a local hardware or plumbing supplier to obtain the correct fittings.
  • Page 9 1. Locate and turn off the angle stop valve on the cold water line feeding the sink where the Sierra unit is to be installed. This valve will usually be located under the sink on the pipe coming out of the wall.
  • Page 10 INSTALLATION Drain Connection Note: The drain saddle assembly must be installed before the 'P' trap. Do not install the drain saddle assembly be- tween the 'P' trap and the wall. Fig.3 1. Position drain saddle assembly (Fig. 3) on drain pipe under sink between the P trap and the sink connection.
  • Page 11 INSTALLATION Drilling The Sink (continued) Fig. 5 2. Clean off sawdust. Enamel, Porcelain-Over-Steel, or Cast Iron Sink 1. With drill motor place 1/4" masonry drill bit at selected location. Before starting rotation, firmly apply downward pressure until a slight crunching sound is heard.
  • Page 12 INSTALLATION Push Handle Faucet For easier installation, attach all tubing prior to mounting the faucet. 1. Insert polished faucet base (refer to figure H page 5) onto base of faucet. 2. Install the 1/4” yellow drain tubing onto the 1/4” barb fitting. This tube must be of sufficient length to reach the yellow manifold drain connection.
  • Page 13 INSTALLATION The Manifold Unit Determine the most practical under-the-sink location for placement of the Sierra manifold unit and the companion reservoir tank. Ensure that the specific location allows adequate access to the manifold unit for cartridge replacement and to the tank for tank- valve operation.
  • Page 14 INSTALLATION Activation/Flushing System Activation and Inspection 1. Check all tubing connections to ensure they are firmly seated. CHECK TO SEE THAT THE CARTRIDGE RETAINER CLIPS ARE PROPERLY ENGAGED. The retainer clips must in place during long term, unattended operation of the system. Failure to keep the retaining clips in place could result in accidental leaks and flooding.
  • Page 15 INSTALLATION Check List 1. Sierra unit and tank are located where they will not be subject to physical impacts or rough contact by heavy objects. 2. Feed water pressure to the unit is no less than 40 psi and no greater than 80 PSI.
  • Page 16 Tank sanitizing should be done every twelve months as part of the regular system maintenance program through an authorized Sierra dealer. This procedure will take approximately 30 min- utes. As a safety precaution, always wear protective eyegear, mix chemicals in a well-ventilated area, and avoid breathing the fumes.
  • Page 17 ©Nimbus Water Systems PN103257 2003...

Table of Contents