C
1. Locate and turn off the angle stop valve on the cold water line feeding the sink. This valve will
usually be located under the sink on the pipe coming out of the wall.
2. When the angle stop valve is closed, relieve pressure in the line by opening the cold water
tap on the sink.
3. Disconnect the feed line at the angle stop valve.
4. If you have a push-to-connect feed connector, install the feed adapter into the angle stop.
Firmly press the green 1/4" tubing into the 1/4" connector.
-OR-
Using the green 1/4" tubing, install the compression nut, plastic ferrule and plastic tube
insert. Secure the tubing into the feed connector. Tighten the tubing retaining nut securely.
5. Connect the cold water faucet feed line to the feed adapter.
7. Attach the small Feed Valve Warning Tag from the parts bag to the feed valve.
8. Attach the Shutoff Warning label to the system so that it is directly visible. Fill out the Date
Of Installation label and attach to the side of the system.
6
Feed Connection
42445 Avenida Alavardo, Temecula, CA 92590
(800) 451-9343, www.nimbuswater.com