Please refer to the Technical Specifications section for more details. WARRANTY ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date (5 years for most products). ORing will repair or replace products found by ORing to be defective within this warranty period, with shipment expenses apportioned by ORing and the distributor.
Tables of Content Getting to Know your Wireless AP Router ..........1 Overview .......................... 1 Software Features ......................1 Hardware Features ......................1 Hardware Installation ..................3 Installation Router on DIN-Rail ..................3 Wall Mounting Installation ....................4 Hardware Overview ..................6 Front Panel ........................
Page 4
Firmware Upgrade ........................ 49 Save/Restore Configurations ....................50 Miscellaneous (Ping) ......................51 Even warning setting......................52 DIDO ........................... 57 5.3.4 System Status ......................57 System Info .......................... 57 System Log........................... 58 Traffic Statistics ........................58 Wireless Link List ......................... 58 Technical Specifications ................
With the 3G WAN connection, the ORing IGAR-1042/1062-3G wireless AP router can be mounted in harsh environment easily to provide internet access anytime and anywhere. The ORing IGAR-1042/1062-3G wireless AP router's VPN capability creates encrypted "Virtual Tunnels"...
Page 6
IGAR-1042/1062-3G Series User’s Manual Casing: IP-30 Dimensions(W x D x H) : 74.3(W) x 109.2(D) x 153.6(H) mm Operating Temperature: -10 to 60 Storage Temperature: -40 to 85 Operating Humidity: 5% to 95%, non-condensing ORing Industrial Networking Corp.
Each Wireless AP router has a DIN-Rail kit on rear panel. The DIN-Rail kit helps AP router to fix on the DIN-Rail. Step 1: Slant the router and mount the metal spring to DIN-Rail. Step 2: Push the router toward the DIN-Rail until you heard a “click” sound. ORing Industrial Networking Corp.
The following steps show how to mount the AP router on the wall: Step 1: Remove DIN-Rail kit. Step 2: Use 6 screws that can be found in the package to combine the wall mount panel. Just like the picture shows below: ORing Industrial Networking Corp.
Page 9
The screws specification shows in the following two pictures. In order to prevent the AP routers from any damage, the screws should not larger than the size that used in IAR-420/620. Pozidrive Step 3: Mount the combined AR on the wall. ORing Industrial Networking Corp.
ETH2 (WAN port) of IGAR-1042+/1062+-3G compliant with IEEE802.3af PoE specifications and can be connected to PoE switches.* ANT. Reversed SMA connector for external antenna. *Note: Please refer to the products of ORing IPS series for P.O.E. Ethernet switch. ORing Industrial Networking Corp.
Data transmitted. Green/Amber Port link up at 10Mbps/1000Mbps. ETH2 Port link up at 100Mbps. Green Blinking Data transmitted. WLAN activated. WLAN Green Blinking WLAN Data transmitted. Green Modem Ready Fault relay. Power failure or Port Fault down/fail. ORing Industrial Networking Corp.
1000Base-T(X) Cat 5e,6 UTP 100 m (328 ft) RJ45 Wireless Antenna 2.4GHz/5GHz antenna is used for IGAR-1042/1062-3G and connected with a reversed SMA connector. External RF cable and antenna also can be applied with this connector. ORing Industrial Networking Corp.
IGAR-1042/1062-3G Series User’s Manual Cellular Antenna 850/900/1800/2100MHz antenna is used for built-in modem. External RF cable and antenna also can be applied with this connector. Cellular Antenna ORing Industrial Networking Corp.
The default gateway IP of IGAR-1042/1062-3G AP router is 192.168.10.1. Start the web browser of your computer and type http://192.168.10.1 in the address box to access the webpage. A login window will popup, and then enter the default login name admin and password admin. ORing Industrial Networking Corp.
Page 16
Click the Basic Setting in the top menu to enter the WAN configuration page, select the proper connection type according to the information of your ISP. If you use modem/3G as WAN connection WAN connection type ORing Industrial Networking Corp.
Page 17
Step 6: Review the router settings and check router status Click the System Status in the top of the menu, the system info page will be shown. You can check all the configuration and status of the router. System status Screen ORing Industrial Networking Corp.
System Tools > Login Setting and change the password. Main Interface The Home screen will be shown when login successfully. Main Interface In the page, you can check the Firmware version, the router running time and the WAN IP setting. ORing Industrial Networking Corp.
Select this option if you would like to assign an IP address to the address WAN port manually. You should set the IP Address, Subnet Mask and Default gateway appropriately so that they comply with IP ORing Industrial Networking Corp.
Page 20
Phone Number, User Name and Password: Use these settings to dial up the Modem/3G connection. Ping Test Site: Use this site address to check if the connection is alive or lost. Take www.google.com as an example. 2. WAN Connection Type: PPPoE ORing Industrial Networking Corp.
Page 21
Phone Number, User Name and Password: Use these settings backup connection to dial up the Modem/3G connection. Ping Test Site: Use this site address to check if the connection is alive or lost. Example is as www.google.com ORing Industrial Networking Corp.
Page 22
If this option is enabled, the connection will be called up when router boots up. Device Status Show the status of Medem/3G device. Click “Connect” to call up the Modem/3G. Click "Disconnect" to Operations shut down the connection. ORing Industrial Networking Corp.
Page 23
WAN port by DHCP server in your network. automatically Use the following IP Select this option if you would like to assign an IP address to the address WAN port manually. You should set the IP Address, Subnet Mask ORing Industrial Networking Corp.
WLAN AP router. The LAN IP address is privately for your internal network and can not be exposed on the Internet. LAN Screen The following table describes the labels in this screen. Label Description IP Address The IP address of the LAN interface, the default IP address is 192.168.10.1 ORing Industrial Networking Corp.
IP from IGAR-1042/1062-3G AP router, it will be assigned with the IP address according to the mapping. You can choose one from the client lists and add it to the mapping relationship. 1. DHCP Sever ORing Industrial Networking Corp.
MAC Address The MAC addresses of the computer. IP Address The IP address to be related to the MAC address. Static DHCP Client The list shows the MAC address and IP address one-to-one List relationship. Wireless ORing Industrial Networking Corp.
Page 27
WPA/WPA2 Personal: WPA -Personal or WPA2-Personal with Security options a pre-shared key, each authorized computer is given the same pass phrase. WPA/WPA2 Enterprise: Wi-Fi Protected Access (WPA) authentication in conjunction with a RADIUS server. 802.1x: Authentication through RADIUS server ORing Industrial Networking Corp.
Page 28
Key 1-4: Input up to four encryption keys. ASCII (American Standard Code for Information Interchange) is a code for representing English letters as numbers from 0-127. Hex digits consist of the numbers 0-9 and the letters A-F. ORing Industrial Networking Corp.
Page 29
Choose one of three Auth Modes: WPAPSK, WPA2PSK, WPAPSK/WPA2PSK Encryption Type: Select TKIP or AES or TKIP/AES mix. Share Key: Enter your pass phase. The pass phase should be between 8 and 64 characters. Security Type – WPA /WPA2 Enterprise ORing Industrial Networking Corp.
Page 30
4. Default Key Index: Select one of the keys to be the active key. 5. Key 1-4: Input up to four encryption keys. 6. Radius Server IP: Enter the IP address of the RADIUS Server. 7. Port: Enter the RADIUS port (1812 is default). ORing Industrial Networking Corp.
Page 31
ISA server may also refuse you to carry a claim according to the authorization strategy of the Radius server. The principle of the Radius server is shown in the following pictures: ORing Industrial Networking Corp.
In this page, you can set the date & time of the device. The correct date & time will be helpful for logging of system events. A NTP (Network Time Protocol) client can be used to synchronize date & time with NTP server through internet. ORing Industrial Networking Corp.
Page 33
Enable or disable NTP function to synchronize time from the NTP server. NTP Server 1 The primary NTP Server. NTP Server 2 The secondary NTP Server. Synchronize This is the scheduled time when the NTP synchronization performed. ORing Industrial Networking Corp.
DTIM Interval value. Its clients hear the beacons and awaken to receive the broadcast and multicast messages. Fragmentation This value should remain at its default setting of 2346. Threshold range is 256-2346 bytes. It specifies the maximum size for a ORing Industrial Networking Corp.
X-Roaming setting interface The following table describes the labels in this screen Label Description Roaming Disable: Disable X-Roaming protocol. X-roaming: Enable X-Roaming protocol Scan channel All: scan all support channel Manual: only scan “channel select” value ORing Industrial Networking Corp.
Page 36
This list shows the MAC addresses that are in the selected filter. Connected Clients This list shows the wireless MAC addresses that associated with MAC Address MAC addresses for editing. Apply Click Apply to activate the configurations. ORing Industrial Networking Corp.
The port number of the service used by the Private IP computer. Enable Now Enable the virtual server entry after adding it. Virtual server list Click Edit to edit the virtual service entry, Del to delete the entry. ORing Industrial Networking Corp.
Page 38
The UPnP (Universal Plug and Play) feature allows the devices, such as Internet computers, to access the local host resources or devices as needed. UPnP devices can be automatically discovered by the UPnP service application on the LAN. UPnP Screen ORing Industrial Networking Corp.
Status: This status shows if the entry is valid or not. Firewall Setting 1. IP Filter Filters are used to deny or allow LAN computers from accessing the internet. It also allow or deny WAN hosts to access LAN computers. IP Filter Screen ORing Industrial Networking Corp.
Page 40
Select DROP, ACCEPT and REJECT rule for the entry. MAC Address Enter the MAC address to be filtered. Enable Now Enable the entry after adding it. IP filter list Click Edit for editing the entry, click Del to delete the entry. ORing Industrial Networking Corp.
Open VPN is a full-functioned SSL VPN solution which can accommodates a wide range of configurations including remote access, site-to-site VPNs, WiFi security, and enterprise-scale remote access solutions with load balancing, failover, and fine-grained access-controls. Open VPN Screen ORing Industrial Networking Corp.
Page 42
Enable or disable the function of LZO Compression. Keys Setting Select Auto to use the preset certificates, select Manual to paste your certificates. Please install openvpn client software to generate your certificates and paste them here. For more information, please visit openvpn website. ORing Industrial Networking Corp.
Page 43
Select Auto to use the preset certificates, select Manual to paste your certificates. Please install software for openvpn client to generate your certificates and paste them here. For more information, please visit openvpn website. 3: Open VPN Server VS Client ORing Industrial Networking Corp.
Page 44
PC. The steps are: Right click Network > property > create a new connection > connect to my work space (VPN) > use VPN to internet > enter the user name and password which are set in the page. PPTP VPN Screen ORing Industrial Networking Corp.
Page 45
Enter the IP address range, format is as 192.168.10.xx-xx, connected client will be assigned the IP address. CHAP-Secrets Enter the username and password pairs, format is as user * pass *, multiple username password pairs are allowed. ORing Industrial Networking Corp.
Page 46
3. PPTP Client If the router A want to link with the others which is not in the same network with the router A, the function of PPTP client should support in the router page. PPTP VPN Line ORing Industrial Networking Corp.
Page 47
Point-to-Point Encryption) to encrypt data across Point-to-Point Protocol (PPP) and Virtual Private Network links. Operations Click “Connect” to link the server, if or not, you can click “”Disconnect” to break off from the server. Link Status Show the status about the link. ORing Industrial Networking Corp.
This page shows the information of routing table. The initial state of the router connect to the WAN, it will be based on the outside networks to access the routing table automatically. You can refer the shows about the bellow page. The table shows the normal routing table ORing Industrial Networking Corp.
Page 49
RIPv1 &v2 Choose “Disable” in the Static routing. Telnet Setting Only use in the Dynamic routing. Simultaneously, only use the Telnet function in the dynamic routing. You can telnet the LAN IP and there are many orders. ORing Industrial Networking Corp.
Page 50
Route Entry, which shows the network segment of the other router. Use the dynamic routing; it will have many ways such as RIP, OSPF.BGP. In this router, we use the RIP Protocol to finish the dynamic routing table. ORing Industrial Networking Corp.
Page 51
RIP, Routing Information Protocol, is a dynamic routing protocol used in local and wide area networks. As such it is classified as an interior gateway protocol (IGP) using the distance-vector routing algorithm. After all settings, PC1 can visit PC2 which is different network segment of the PC1. ORing Industrial Networking Corp.
'0-9', 'a-z', 'A-Z' and must be between 0 to 15 characters in length. Confirm New Password Retype the password to confirm it. Acceptable inputs of this field contains '0-9', 'a-z', 'A-Z' and must be between 0 to 15 characters in length. ORing Industrial Networking Corp.
AP router. It will take several minutes to upload and update the firmware. After the upgrade is done successfully, reboot the router to utilized new firmware. Important Notice: DO NOT POWER OFF THE ROUTER OR PRESS THE RESET ORing Industrial Networking Corp.
Click Upload when you have selected the file. Restore Default You may also reset the router to the factory settings by clicking on Settings Restore Default Settings. The router will reboot to validate the default settings. ORing Industrial Networking Corp.
The Ping Test is used to send Ping packets to test if a computer whether it is on the Internet or test if the WAN connection is OK. Enter a domain or IP in the destination box and click Ping to test. ORing Industrial Networking Corp.
The following table describes the labels in this screen. Label Description Syslog Server IP Not only the syslog keeps the logs locally, it can also log to remote server. Specify the IP of remote server. Leave it blank to disable logging remotely. ORing Industrial Networking Corp.
Page 57
IGAR-1042/1062-3G Series User’s Manual Syslog Server Port Specify the port of remote logging. Default port is 514. 2. E-Mail ORing Industrial Networking Corp.
Page 58
Simple Message Transfer Protocol, enter the backup host to use if primary host is unavailable while sending mail by SMTP server. Server Port Specify the port where MTA can be contacted via SMTP server. E-mail Address 1-4 Inputs specify the destination mail address. ORing Industrial Networking Corp.
Page 60
Specify the IP of trap server, which is the address to which it will send traps AP generates. Community Community is essentially password to establish trust between managers and agents. Normally "public" is used for read-write community. SysLocation Specify sysLocation string. SysContact Specify sysContact string. 4.Relay Relay setting interface ORing Industrial Networking Corp.
IGAR-1042/1062-3G Series User’s Manual DIDO 5.3.4 System Status System Info System Info Screen This page displays the details information for the AP router including model name, model description, firmware version, WAN, LAN and wireless settings. ORing Industrial Networking Corp.
This page displays the network traffic statistics for both received and transmitted packets through the Ethernet port and wireless connections. Wireless Link List This page of the list displays the Mac Address of the wireless clients connected. ORing Industrial Networking Corp.
Page 64
74.3(W) x 109.2(D) x 153.6(H) mm Casing IP-30 protection Regulatory Approvals FCC Part 15, CISPR (EN55022) class A EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 Shock IEC60068-2-27 Free Fall IEC60068-2-32 Vibration IEC60068-2-6 Rail Traffic EN60950-1 ORing Industrial Networking Corp.
Page 65
“Digital Apparatus,” ICES-003 of Industry Canada. Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matérial brouilleur: “Appareils Numériques,” NMB-003 édictée par l’Industrie. ORing Industrial Networking Corp.
Page 66
Avertissement d'exposition RF: L'équipement est conforme aux limites d'exposition aux RF établies pour un incontrôlés environnement. L'antenne (s) utilisée pour ce transmetteur ne doit pas être co-localisés ou fonctionner en conjonction avec toute autre antenne ou transmetteur. ORing Industrial Networking Corp.
Need help?
Do you have a question about the IGAR-1042 series and is the answer not in the manual?