Activation And Setup Parameter Adjustment - Kemppi Master S 400 Operating Instructions Manual

Hide thumbs Also See for Master S 400:
Table of Contents

Advertisement

3.2.3 Activation and setup parameter adjustment

1.
Press remote selection button (11) for at least 3 seconds, until the text "Set" appears on
the screen.
2.
Choose the needed parameter with the welding current adjustment knob (6).
3.
To select the required parameter, press the remote selection button (11). You can move
from adjustment mode to selection mode with a new press of the button (11).
4.
Use the Welding current adjustment knob (6) to adjust the parameter value.
5.
You can exit Setup mode with a long press of remote selection button (11). Setup
parameters are saved when you exit Setup.
Setup menu structure
Advanced control panel
Name
Ant.
EN
Cab.
Gen.
CU
rc
rcL
rcH
Urd
Fac.
Constant Voltage (CV)
In CV mode the welding machine maintains a relatively stable, consistent voltage regardless
of the amperage. This mode is recommended to be used with carbon arc gouging and in MIG/
MAG welding with Kemppi voltage sensing wire feed systems. CV mode is activated through
the setup menu.
Voltage Reduction Device (VRD)
Master S 400 and 500 contain a voltage reduction device (VRD), which reduces the open-
circuit voltage below 35 V. This reduces the risk of electric shock in particularly dangerous
environments, such as closed or damp spaces. VRD is activated through the setup menu.
8
Master S 400, 500
Function
Description
Antifreeze
If Antifreeze selection is On, the
machine cuts off the power and protects
the electrode if sticking occurs during
the welding
Long cables
Long cable mode for welding circuits of
50 m and longer (max. 80 m)
Generator
Generator mode for generator use and
fluctuating mains networks
CV mode
CV mode selection
Remote selection
Remote operation mode. Selection
between analog and wireless remote
controllers (R10/R11T)
Remote low current
Limits the remote adjustment range.
limit
Allows more exact remote adjustment.
Remote high current
Limits the remote adjustment range.
limit
Allows more exact remote adjustment.
VRD selection
Reduces open circuit voltage below 35V OFF
Restore factory
Restores setup and panel settings to
settings
factory default
Factory
Adjustment range
default
On
On/OFF
OFF
On/OFF
OFF
On/OFF
OFF
On/OFF
r10
r10/r11
30
30–MAX
MAX
30–MAX
On/OFF
(device specific)
OFF
rES/OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Master s 500

Table of Contents