Download Print this page

Connection Diagram - Bosch PR111B Reference Manual

External lan reader modules

Advertisement

PR111B-PR112B
Installer Reference Guide

Connection Diagram

The optional CM444B relay module provides
an easy way to interface the readers lock
Because of its small physical size
(12.5 x 46 x 12mm) it can be easily located
in the wall cavity if required.
CM720B or CM723B
Power Supply
(Battery backed up)
DOOR
LOCK
+
PROTECTION
DIODE
Wiring Legend
RED
= LAN +
BLACK
= LAN -
WHITE
= LAN A
BLUE
= LAN B
YELLOW
= LOCK
GREEN
= EGRESS
You must power cycle the panel or perform
i
a LAN scan after connecting the PR111B or
Note
PR112B for the system to initialise the reader.
6
output to the door lock.
CM444B RELAY CARD
CM444 Relay Card
N/O
COM
DF70
N/C
TO
DOOR
LOCK
EGRESS
INPUT
Figure 4: PR111B and PR112B Connection Diagram
Address Select Switch. Keypads and LAN
Readers must be set to a unique address as
per "Table 2: Address Table" on page 2
All LAN Readers are supplied from
the factory set to Address 1.
+12V
YL
Lock
BL
Output
WH
BK
RD
GN
Egress
Input
The egress input
is low (0V) to trigger.
Disable via panel
programming if not
being used.
Bosch Security Systems 09/11 PR111B-PR112BIRG FTR1.1
PR111 LAN Reader
P/N:
PR111B
MFG:
30-Jul-2011
S/N:
00542754
N12138
Make sure that the
keypad buzzer opening
is not blocked
during installation
or the volume will be
greatly reduced.

Advertisement

loading

This manual is also suitable for:

Pr112b