File No.
960-010
PROCEDURE 2
Message Check
1.
When the power switch is turned on after the
diagnostics disk is inserted into the FDD, message (a),
(b), or (c) shown below may appear.
(a)
*** FDD A is not installed ***
(b)
Non-System disk or disk error
Replace and press any key when ready
(c)
** FDD load error or Bad system disk **
Insert system disk in drive
Press any key when ready .....
2.
If message (a) is displayed, check that the A-B-PRT
switch is set to PRT. If it is not set to PRT, set it
to PRT. If it is set to PRT, go to PROCEDURE 5.
3.
If message (b) or (c) is displayed, the contents of the
floppy disk is damaged, or a disk other than the
diagnostics disk has been inserted into the FDD.
Insert a new diagnostics disk into the FDD.
If loading
completes, go to PROCEDURE 4.
If loading does not
complete, go to PROCEDURE 3.
4.
If none of the above messages appears, go to PROCEDURE
5 .
2-19