Error Information - Panasonic AG-HPD24P Operating Instructions Manual

Memory card portable recorder
Hide thumbs Also See for AG-HPD24P:
Table of Contents

Advertisement

Warning information displayed in 3D REC/PB mode and SYNC PB mode
Message
ERROR
REF IN NOT DETECT
ERROR
USB DISCONNECT
ERROR
SLAVE IS BUSY
ERROR
SERIAL NO. MISMATCH
ERROR
VERSION FIRMWARE MISMATCH
ERROR D-SUB DISCONNECT
WAITING FOR CONNECTION

Error Information

Error
No.
Message
E-30
TURN POWER OFF
E-31
REC ERROR
E-37
COMM ERROR
E-38
SYSTEM ERROR
E-BA
BATTERY
E-80
LINK D-SUB DISCONNECT
E-81
LINK USB DISCONNECT
E-83
SLAVE ERROR
E-84
MASTER ERROR
• If an error occurs, the OSD alternately displays an error number and "AUTO OFF".
Description
A reference signal has not been connected or the
slave side is not powered up.
The LINK (USB) connection signal could not be
detected after 2 minutes.
Mode changes cannot be made during slave side
operation. This message may also appear during
startup when the slave side is started up
simultaneously with or after master side startup.
The LINK (D-SUB) cable and the LINK (USB) cable
is not connected to the same device.
The connected devices are using different firmware
version.
The LINK (D-SUB) cable is not connected.
The unit is waiting for connection for it takes time to
detect the synchronized connection of the two
units.
Displayed when an error occurs in reading and writing card data.
To continue operation, turn the power off and then back on again.
Displayed when an error occurs during recording. To continue operation, turn the power
off and then back on again.
Displayed when a system controller command was not complied to.
To continue operation, turn the power off and then back on again.
Displayed when a communication error has occurred.
To continue operation, turn the power off and then back on again.
Appears when the input DV voltage is below the undercut voltage.
Displayed when a LINK D-SUB cable for the 3D REC/PB mode and SYNC PB mode is
disconnected or other error occurs. Turn off the power and check the connection before
use.
Displayed when a LINK USB cable for the 3D REC/PB mode and SYNC PB mode is
disconnected or other error occurs. Turn off the power and check the connection before
use.
The slave side was turned off (AUTO OFF). Use after turning the slave and master sides
off.
The master side was turned off (AUTO OFF). Use after turning the master and slave sides
off.
For Long and Trouble-Free Operation: Warning and Error Messages
Turn on the slave side and check connection of the
reference signal line.
Check LINK (USB) cable connection.
Turn on the slave side. If the error persists after the
slave side starts operation, check the slave side.
Displayed during slave side operations such as
recording, playback, menu display or remote
status.
Cancel the remote status, menu display, or other
operation to enter the STOP status.
Connect the cables to the same device.
Connect devices with the same firmware version.
Connect the LINK (D-SUB) cable.
If the signal cannot be detected in 2 minutes, an
error is generated. Locate the cause of the error
before connecting again.
Description
Measure
Operation
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
89