16 Technical data

Air to water heat pump
Refrigerant
Type
Amount
Test pressure
Design pressure
Compressor
Type
Oil
Electrical data
Main supply
3-N~50Hz
Rated power compressor
Rated power, circ.pumps/fan
Auxiliary heater, 5 steps
Start current
Circuit breaker
Electrical data
Main supply
1-N~50Hz
Rated power compressor
Rated power, circ.pumps/fan
Auxiliary heater, 3 steps
Start current
Circuit breaker
Performance
Heating capacity
10
COP
Heating capacity
COP
Power input
Nominal flow
Cooling circuit
8
Heating circuit
External available pressure
9
Cooling circuit
Heating circuit
Lowest outdoor temperature allowed for compressor start
Max/min temperature
Cooling circuit
Heating circuit
Pressure switches
Low pressure
Operating
High pressure
Water volume
Water heater
Condensor
Evaporator
Anti freeze media
13
Number of units
Indoor unit
Dimensions LxWxH
Weight empty
Weight filled
Sound power level
Outdoor unit
Dimensions LxWxH
Weight empty
Weight filled
Sound power level, low/high
Fan speed low/high
Air flow low/high
Max. pipe length (Cu pipe Ø 28 mm between heat pump and outdoor unit)
The measurements are performed on a limited number of heat pumps which can cause variations in
the results. Tolerances in the measuring methods can also cause variations.
1)
At A2W35 according to EN 14511 (including circulation pumps and outdoor unit).
At A7W35 according to EN 14511 (including circulation pumps and outdoor unit).
2)
Heat pump with 3 kW auxiliary heater (1-N 1.5 kW).
3)
Heat pump with 6 kW auxiliary heater (1-N 3 kW).
4)
5)
Heat pump with 9 kW auxiliary heater (1-N 4.5 kW).
6)
12 kW auxiliary heater (compressor off).
7)
15 kW auxiliary heater (compressor off).
8)
Nominal flow: heating circuit Δ10K, cooling circuit Δ3K.
9)
Pressure drop that must not be exceeded outside the heat pump without the nominal flow being
reduced.
86
DHP-A Opti
1
1
2
2
2
11
12
6
8
R404A
R404A
kg
0,95
1,45
MPa
3,4
3,4
MPa
3,10
3,10
Scroll
Scroll
POE
POE
Volt
400
400
kW
2,0
2,3
kW
0,4
0,4
kW
3/6/9/12/15
3/6/9/12/15
A
14
25
A
10
3
/16
4
/20
5
/20
6
16
3
/16
4
/20
5
/20
/25
/25
/30
/25
/25
/30
7
14
15
7
14
Volt
230
230
kW
3,3
4,2
kW
0,4
0,4
kW
1,5/3,0/4,5
1,5/3,0/4,5
A
58
76
A
25
/32
/40
25
/32
/40
3
3
4
5
4
kW
5,00
7,02
2,85
3,10
kW
5,90
7,96
3,26
3,45
kW
1,8
2,3
l/s
0,32
0,49
l/s
0,14
0,22
kPa
88
74
kPa
103
102
C
-20
-20
o
o
C
20/-25
20/-25
o
C
55/20
55/20
MPa
0,08
0,08
MPa
2,65/2,85
2,65/2,85
MPa
3,10
3,10
l
180
180
l
1,3
2,2
l
1,0
1,3
Ethylene Glycol + Water solution with a freezing point below -30 °C
2
2
mm
690x596x1845
690x596x1845
kg
260
260
kg
440
440
dB(A)
42,5
47,7
630x1175x1245
630x1175x1245
mm
kg
94
94
kg
99
99
dB(A)
53/63
53/63
rpm
450/600
450/600
m
3
/h
2500/3200
2500/3200
m
210 (105+105)
131 (65+65)
10
) The values apply to a new heat pump with clean heat exchangers.
11)
Sound power level measured according to EN ISO 3741 at A7W45 (EN 12102).
12)
Sound power level measured according to EN ISO 3741.
Propylene glycol or ethanol may not be used.
13)
Heat pump with 12 kW auxiliary heater.
14)
Heat pump with 15 kW auxiliary heater.
15)
VMBMA602
10
12
R404A
R404A
1,50
1,60
3,4
3,4
3,10
3,10
Scroll
Scroll
POE
POE
400
400
3,6
4,4
0,5
0,6
3/6/9/12/15
3/6/9/12/15
29
32
6
16
3
/16
4
/20
5
/20
6
16
3
/20
4
/25
5
/25
/25
/30
/35
/25
/30
/35
15
7
14
15
7
14
15
230
230
5,4
5,7
0,5
0,6
1,5/3,0/4,5
1,5/3,0/4,5
97
108
32
/40
/50
32
/40
/50
3
3
5
4
5
4
5
8,20
9,84
2,85
3,00
9,85
11,3
3,29
3,35
3,0
3,4
0,58
0,64
0,22
0,28
56
98
101
93
-20
-20
20/-25
20/-25
55/20
55/20
0,08
0,08
2,65/2,85
2,65/2,85
3,10
3,10
180
180
2,7
2,7
1,3
1,6
2
2
690x596x1845
690x596x1845
260
268
440
448
45,5
48,1
630x1175x1245
630x1175x1245
94
94
99
99
54/67
54/67
500/800
500/800
2500/3900
2500/3900
70 (35+35)
76 (38+38)
6