Brine to water heat pump
Refrigerant
Type
Amount
Test pressure
Design pressure
Compressor
Type
Oil
Electrical data
Main supply
3-N~50Hz
Rated power compressor
Rated power, circ.pumps
Auxiliary heater, 3 steps
Start current
Circuit breaker
Electrical data
Main supply
1-N~50Hz
Rated power compressor
Rated power, circ.pumps
Auxiliary heater, 3 steps
Start current
Circuit breaker
Performance
10
Heating capacity
COP
Heating capacity
COP
Power input
Nominal flow
Cooling circuit
8
Heating circuit
External available pressure
7
Cooling circuit
Heating circuit
Max/min temperature
Cooling circuit
Heating circuit
Pressure switches
Low pressure
Operating
High pressure
Water volume
Water heater
Condensor
Evaporator
De-superheater
Anti freeze media
Number of units
Dimensions LxWxH
Weight empty
Weight filled
Sound power level
11
The measurements are performed on a limited number of heat pumps which can cause variations in
the results. Tolerances in the measuring methods can also cause variations.
1)
At B0W35 according to EN 14511 (including circulation pumps).
At B0W45 according to EN 14511 (including circulation pumps).
2)
According to IEC61000.
3)
Heat pump with 3 kW auxiliary heater (1-N 1.5 kW).
4)
5)
Heat pump with 6 kW auxiliary heater (1-N 3 kW).
6)
Heat pump with 9 kW auxiliary heater (1-N 4.5 kW).
7)
Pressure drop that must not be exceeded outside the heat pump without the nominal flow being
reduced. For the cooling circuit these values require a pipe of Ø 40x2.4.
8)
Nominal flow: heating circuit Δ10K, cooling circuit Δ3K.
Fuse protection phase L1 (size 4 is equipped with an 1-phase compressor)
9)
92
DHP-H
kg
MPa
MPa
Volt
kW
kW
kW
A
3
A
Volt
kW
kW
kW
A
A
1
kW
1
kW
2
2
1
kW
l/s
l/s
kPa
kPa
C
o
C
o
MPa
MPa
MPa
l
l
l
l
mm
kg
kg
dB(A)
4
6
R407C
R407C
0,75
1,20
3,4
3,4
3,1
3,1
Scroll
Scroll
POE
POE
400
400
2,7
2,0
0,2
0,2
3/6/9
3/6/9
17
12
16
+10
/10
/16
10
/16
/20
9
4
5
6
4
5
6
230
230
2,7
3,3
0,2
0,2
1,5/3,0/4,5
1,5/3,0/4,5
17
58
20
/25
/32
25
/32
/40
4
5
6
4
5
6
3,52
5,33
3,90
4,04
3,42
5,38
3,05
3,41
0,9
1,3
0,20
0,36
0,09
0,14
37
39
52
51
20/-10
20/-10
55/20
55/20
0,08
0,08
2.65/2.85
2.65/2.85
3,10
3,10
180
180
0,8
1,6
0,7
0,7
*
*
Ethylene glycol/
Ethylene glycol/
Ethylene glycol/
Ethanol
Ethanol
1
1
690x596x1845
690x596x1845
690x596x1845
225
229
405
409
45,5
47,3
10)
The values apply to a new heat pump with clean heat exchangers.
11)
Sound power level measured according to EN ISO 3741 at BOW45 (EN 12102).
*
)
Not available in this version.
VMBMA602
8
10
R407C
R407C
1,30
1,45
3,4
3,4
3,1
3,1
Scroll
Scroll
POE
POE
400
400
2,3
3,6
0,2
0,4
3/6/9
3/6/9
10
18
16
/16
/20
16
/16
/20
16
4
5
6
4
5
6
230
230
4,2
5,4
0,2
0,4
1,5/3,0/4,5
1,5/3,0/4,5
1,5/3,0/4,5
76
97
25
/32
/40
32
/40
/50
32/40/50
4
5
6
4
5
6
7,51
9,40
4,34
4,24
7,40
9,24
3,57
3,51
1,7
2,2
0,49
0,62
0,19
0,24
39
78
44
40
20/-10
20/-10
55/20
55/20
0,08
0,08
2.65/2.85
2.65/2.85
2.65/2.85
3,10
3,10
180
180
1,9
2,1
1,2
1,6
*
*
Ethylene glycol/
Ethylene glycol/
Ethanol
Ethanol
1
1
690x596x1845
690x596x1845
229
229
409
409
43,7
45,6
12
16
R407C
R407C
1,55
2,00
3,4
3,4
3,1
3,1
Scroll
Scroll
POE
POE
400
400
4,4
5,6
0,5
0,5
3/6/9
3/6/9
17
18
/20
/25
20
/20
/25
4
5
6
4
5
6
230
*
5,7
*
0,5
*
*
108
*
*
6
11,0
16,4
4,20
3,99
10,6
15,6
3,39
3,19
2,6
4,1
0,71
1,02
0,28
0,39
70
37
59
54
20/-10
20/-10
55/20
55/20
0,08
0,08
2.65/2.85
3,10
3,10
180
180
2,1
2,9
1,6
2,2
*
*
Ethylene glycol/
Ethanol
Ethanol
1
1
690x596x1845
238
242
418
422
48,5
56,8