Message
Meaning
START
Indicates that there is a demand for heating production and that no start delay is active.
EVU STOP
Indicates that the additional function EVU is active. This means that the heat pump is off as
long as EVU is active.
NO DEMAND HEAT
Indicates that there is no heating production demand.
HIGHPRESS ERROR
Alarm that indicates that the high pressure switch has deployed.
LOWPRESS ERROR
Alarm that indicates that the low pressure switch has deployed.
MOTOR P ERROR
Alarm that indicates that the motor protection has deployed.
BRINEFLOW LOW
Appears if the accessory flow switch is installed. Alarm that indicates that the flow in the
brine system is low.
SENSOR
Alarm that indicates a faulty sensor.
HEATPUMP START --MIN
Indicates that there is a heating production demand and will start in the specified number
of minutes.
HEATPUMP+ADD.HEAT
Indicates that heat production is active with both compressor and auxiliary heater.
START_MIN
Indicates that there is a demand for heating production but that a start delay is active.
ADD. HEAT
Indicates that there is an auxiliary heater demand.
COOLING
Displayed if cooling is passive.
COOLING A
Displayed if cooling is active.
DEFROST
Displayed if defrosting is active. (DHP-A, -AL)