13.2

Display

The display of the control computer shows information about the heat pump's operation, status and any alarms, in text form. The status,
indicated by symbols, is also shown in the lower section which shows the heat pump's active process.
Operating mode
Appears with applicable heat pump operating status text.
Operating mode
(OFF)
AUTO
HEATPUMP
ADD. HEAT
HOT WATER
Symbols
Displays the operating status of the heat pump using symbols.
Symbol
HP
LIGHTNING
HOUSE
TAP
F
FLOW
GUARD
CLOCK
TANK
SQUARE
DEFROST
FAN
COOLING
Text
Appears with applicable heat pump operating status text.
Message
ROOM
ERR PHASE SEQ.
HIGH RETURN
50
Meaning
The installation is fully switched off.
Remember that if the operating mode OFF is to be used for long periods during
the winter, the water in the heating system in the installation must be drained,
otherwise there is a risk of frost damage.
The heat pump and the auxiliary heater are automatically controlled by the control computer.
The control computer is controlled so that only the heat pump unit (compressor) is allowed to
operate. In this operating mode peak heating charging (legionella function) of the hot water
will not be run because additional heat must not be used.
The control computer only permits the auxiliary heater to be in operation. This operating
mode can be used when a new installation is being used, when the brine system is not ready
for operation.
In this mode the heat pump only produces hot water, no heat goes to the heating system.
Meaning
Indicates that the compressor is in operation.
Indicates that the auxiliary heater is in operation. Number of auxiliary power stages indicated
by digit.
Indicates that the 3-way valve position is for heat production for the house.
Indicates that the 3-way valve's position is for hot water production.
An "F" next to the symbol indicates that a flow guard is installed.
Indicates that tariff control is active.
Indicates the level of hot water in the water heater. During charging, the tank is filled and fill-
ing starts at the set start temperature. A lightning symbol by the symbol indicates peak heat-
ing charging (legionella function).
Either indicates that the operating pressure switch has deployed, or that the hot gas tempera-
ture has reached its maximum temperature.
Displayed if defrosting is active. (DHP-A, -AL)
Displayed if the fan is active L=Low speed and H= High speed. (DHP-A, -AL)
Indicates Cooling. A indicates active cooling.
Meaning
Shows the set ROOM value. Standard value: 20°C.
If the accessory room sensor is installed it shows the actual temperature and the desired
indoor temperature within brackets.
Alarm that indicates that there is an incorrect phase sequence to the compressor. Only dis-
play and only the first 10 minutes.
Alarm that indicates that the high return temperature prevents the compressor's operation.
VMBMA602