Danfoss DHP-H Installation And Service Instructions Manual page 59

Table of Contents

Advertisement

Menu selection
ALARM
(Expansion card)
SHUNT COOLING
(Expansion card)
SHUNTGROUP
(Expansion card)
COOLING PASSIVE
(Expansion card)
HGW-SHUNT
(DHP-H Opti Pro)
COOLING ACTIVE
(Expansion card)
VXV POOL
(Expansion card)
0-10V
(Expansion card)
Sub menu SERVICE -> INSTALLATION
Used for settings that are set during installation
Menu selection
SWEDISH
SYSTEM
NOTE! The menu selec-
tion in the SYSTEM menu
varies depending on the
selected values. Tip: start
in the top menu and
work downwards.
Meaning
0 = stop signal on output External alarm
1 = start signal on output External alarm
- = shuts shunt
0 = shunt unaffected
+ = opens shunt
- = shuts shunt
0 = shunt unaffected
+ = opens shunt
0 = stop passive cooling
1 = start passive cooling (brine pump starts and shunt cooling regulates to set
point value)
- = shuts shunt
0 = shunt unaffected
+ = opens shunt
0 = stop active cooling
1 = start active cooling (brine pump and compressor starts, shunt cooling regu-
lates to set point value)
0 = normal mode for exchange valve
1 = pool mode for exchange valve
For any future demands.
Meaning
Language setting for the control computer.
Sub menu SERVICE -> INSTALLATION -> SYSTEM:
Menu selection
Meaning
HEAT SOURCE
GROUND OR ROCK
OUTSIDE AIR
Menu selection
DIRECT EVAPURATION
BRINE SOLUTION
HEATING SYSTEM
VL-SYSTEM
D-SYSTEM
VLD-SYSTEM (appears if OUTSIDE AIR is selected)
COOLING
PASSIVE COOLING:
(Expansion card)
ACT COOLING:
ROOM SENSOR: 0/1 (Appears if room sensor is installed)
(0=controls to a constant value, 1=controls to the value that the room sensor has)
(The menu option INTEGRATED IN HP only applies to the DHP-C* heat pump)
POOL
ON /
(Expansion card)
Does not appear if SHUNT GROUP is selected.
SHUNTGROUP
ON /
(Expansion card)
When ON, HEAT CURVE 2 is activated in the INFORMATION menu. Not displayed if
POOL is selected.
ADD. HEAT
0-10V:
FLOW SENSOR: ON /
CURRENT LIMITER: ON /
PHASE FAULT:
/EXTERNAL/INTEGRATED IN HP
/EXTERNAL
/ EXTERNAL ADDITIONAL HEATER (Expansion card)
(Expansion card)
/ PHASE READING
VMBMA602
Factory setting
-
-
-
-
-
-
-
-
Factory setting
SWEDISH
(SVENSKA
NORSK,
SUOMI,
DEUTSCH,
NEDERLANDS,
ENGLISH,
FRANCAIS
POLSKI
DANSK)
Meaning
59