DHP-AL, connection diagram VLD
23
22
20
19
21
6
7
1
Figure 49:
General connection diagram DHP-AL, system VLD.
Position Name
1
Heat pump (part of the delivery)
2
Supply line
3
Return line
4
Safety valve
5
Expansion tank
6
Strainer (part of the delivery)
7
Flexible hoses (part of the delivery)
8
-
9
Mixer valve
10
Exchange valve
11
Safety valve (9 bar) (included in delivery)
12
Vacuum valve
13
Non-return valve
14
Shut-off valve
15
Cold water
16
Hot water
17
Water heater (part of the delivery)
18
Bleed valve at stainless steel water heater
19
External auxiliary heater
20
Circulation pump
21
Non-return valve
22
Moved supply line sensor (included in heat pump)
23
Auxiliary shunt
24
Safety valve for temperature and pressure (mounted only on cer-
tain models, see chapter 6)
6.4

Safety valves

Radiator systems with a closed expansion tank must also be
equipped with an approved pressure gauge and safety valve,
minimum DN 20, for a maximum 1.5 bar opening pressure, or
according to country specific requirements.
Cold and hot water pipes as well as overflow pipes from
safety valves must be made of heat resistant and corrosion-
resistant material, e.g. copper. The safety valve overflow pipes
must have an open connection to the drain and visibly flow
into this in a frost-free environment.
The connecting pipe between the expansion tank and the
safety valve must slope continuously upwards. A continuous
upwards slope means that the pipe must not slope down-
wards from the horizontal at any point.
6.5

Connecting cold and hot water pipes

1. Connect the cold water and hot water pipes with all the neces-
sary components according to the connection diagram for the
relevant system.
10
2
3
11
4
12
13
14
5
24
13
14
18
17
7
6.6
Connecting the heating system supply
and return lines
All pipes should be routed in such a way that vibrations cannot be
transmitted from the heat pump through the piping and out into
the building. This also applies to the expansion pipe. To avoid the
transmission of vibrations, we recommend that flexible hoses are
used for the supply line and return line on both the heating system
and brine system sides. Flexible hoses are available to purchase
from Danfoss AS. The figures below show how appropriate and
inappropriate installations look using this type of hose.
To avoid noise caused by pipe mounting, rubber-coated clamps should
15
be used to prevent the transmission of vibrations. However, installation
should not be too rigid and the clamps must not be too tight.
16
Figure 50:
Do not twist the flexible hoses as they are installed. At
threaded connections, use a counterhold spanner.
Figure 51:
Cut the hose to the correct length to avoid excess
bowingout or stretching at bends.
Figure 52:
Cut the hose to the correct length to avoid excess bowing-
out or stretching and offset the ends so that the hose is not
installed completely straight.
Figure 53:
Use fixed pipe bends to avoid excess stress on bends next to
connections.
1. Connect the supply line with a flexible hose connection and
with all the necessary components.
2. Connect the return line with a flexible hose connection and
with all the necessary components including a filter.
3. Insulate the supply and return lines.
4. Connect the expansion tank to the expansion outlet (22mm Cu)
on the top of the heat pump.
VMBMA602
27