Mode Operation - VENDAPIN DATATRON III SERIES 5882 Operator's Manual

Table of Contents

Advertisement

I n t e r f a c e C o n n e c t o r a n d S e t t i n g s
The white AMP Mate-n-Lok connector on the Datatron III interfaces with third-party vending
devices, such as copiers, duplicators, and printers. Pre-assembled machine-specific harnesses with
installation instructions from VENDAPIN are available for most devices. Please have your copier
type ready when you call to order.
Note: Incorrectly wiring your machine harness will result in equipment malfunction and/or
damage. Pay careful attention to the instructions that came with your machine specific
machine harness. Optos are polarity sensitive.
PIN and Color
1 - Blue
2 - Green
3 - Purple
4 - Gray
5 - White
6 - Yellow
7 - Not Used
8 - Not Used
9 - Not Used

Mode Operation

Standard Mode uses
• An enable relay closure to allow the copy process to begin.
• A pulse back on Opto 1 from the copier indicates that a Price-1 copy has been completed.
• A pulse back on Opto 2 from the copier indicates that a Price-2 copy has been completed.
Steering Mode uses
• An enable relay closure to allow the copy process to begin.
• A pulse back on Opto 1 from the copier indicates that a copy has been completed.
• A steady low level on Opto 2 line indicates the copy is Price-1.
• A steady high level on Opto 2 line indicates the copy is Price-2.
Copier Interface Connector
Pinout for 9 Pin AMP Interface Connector
Standard Mode
Normally Open (Enable)
Common (Enable)
(-) Count Signal {3V-24V} –
(Price 1)
(+) Count Signal {3V-24V} –
(Price 1)
(+) Count Signal {3V-24V} –
(Price 2)
(-) Count Signal {3V-24V} –
(Price 2)
Steering Mode
Normally Open (Enable)
Common (Enable)
(-) Opto 1
(+) Opto 1
(+) Opto 2
(-) Opto 2