Connecting the DV-46DVA-GCL Adapter to Appliance

Top Vent

• Remove top seal cap and insulation if equipped. See
Section 14, "Appliance Setup." Attach the DVP-2SL to
the 8 inch starting collar. Follow installation instructions
included with DVP-2SL kit. Attach the DV-46DVA-GCL
adapter to the appliance starting collar with 3-1/2 in.
self-tapping screws. See Figure 4.25.

Rear Vent

• Remove the rear seal cap and insulation if equipped.
Connect the DVP-2SL adapter to the vertically positioned
elbow. Follow installation instructions included with DVP-
2SL kit. Secure DV-46DVA-GCL adapter to DVP-2SL with
3-1/2 in. self-tapping screws. See Figure 4.25.
Connecting the LINK-DV30B to the DV-46DVA-GCL
adapter
• Insert the two sections of fl exible vent pipe down the
existing chimney.
• Attach one section of stainless steel fl ex pipe to the
exhaust collar on top of the DV-46DVA-GCL adapter with
EXISTING CHIMNEY
EXHAUST AIR
VENT PIPE
EXISTING CHIMNEY
COAXIAL/COLINEAR
APPLIANCE CONNECTOR
DVP-2SL
DIRECT VENT FIREPLACE
HEARTH
FLOOR
H
Minimum
10 ft.
Maximum
40 ft.
Figure 4.25
REAR VENT
TERMINATION CAP
CAUTION! DO NOT use any fl ue restric-
tor when venting with the DV-46DVA-GCL
adapter and LINK-DV30B kit. This may re-
sult in poor fl ame appearance, sooting, pilot
malfunction, or overheating.
NOTICE: To achieve optimum perfor-
V
mance of appliance, minimize or avoid
bends in exhaust vent pipe.
INLET AIR VENT PIPE
The first 3 feet of
exhaust flue must be
stainless flex pipe.
To minimize cold air
drafts, seal with
non-combustible
insulation.
V
H
3.05 m
0 ft.
0 mm
12.2 m
2 ft.
610 mm
Heatilator • ECLIPSE-32, ECLIPSE-36 Installation Manual • 2297-984 Rev. B • 6/15
three screws.
• Attach one section of fl exible vent pipe to the stainless
steel fl ex pipe with three self-tapping screws.
• Attach one section of fl exible vent pipe to the inlet collar
on top of the DV-46DVA-GCL adapter with three self-
tapping screws.
• To minimize cold air drafts, seal around the fl ex vents
at the damper inside the chimney with non-combustible
unfaced fi berglass or rock wool insulation.
The DV-46DVA-GCL adapter must be recessed into existing
masonry fi replace. This measurement is taken from the top
of the fi replace opening. See Table 1 and Figure 4.24.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Do NOT connect this gas appliance to a chimney fl ue
serving a separate solid fuel or gas burning appliance.
• Could impair safe operation of this appliance or other
appliances connected to the fl ue.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
EXISTING CHIMNEY
EXHAUST AIR
VENT PIPE
EXISTING CHIMNEY
COAXIAL/COLINEAR
APPLIANCE CONNECTOR
DVP-2SL
DIRECT VENT FIREPLACE
HEARTH
FLOOR
Minimum
Maximum
TOP VENT
TERMINATION CAP
V
INLET AIR
VENT PIPE
The first 3 feet of
exhaust flue must
be stainless flex
pipe.
To minimize cold air
drafts, seal with
non-combustible
insulation.
V
10 ft.
3.05 m
40 ft.
12.2 m
27