Heatilator ECLIPSE-32 Installation Manual page 53

Hide thumbs Also See for ECLIPSE-32:
Table of Contents

Advertisement

A. Vent Components Diagrams (continued)
8-1/8 in.
(206 mm)
15 in.
(381 mm)
DVP-HRC-SS NOT APPROVED FOR ALL UNITS.
8-1/8 in.
(206 mm)
15 in.
(381 mm)
Figure 12.5 Vent Components
13 in.
(330 mm)
Fire Risk.
• When using SLP-HRC-SS and SLP-HRC-ZC-
SS termination caps on top vented fi replaces,
a one foot minimum vertical vent section is
required before installing fi rst elbow.
• When using DVP-TB1 termination cap on top vented
fi replaces, a three foot minimum vertical vent section is
required before installing fi rst elbow.
13 in.
(330 mm)
HORIZONTAL TERMINATION CAP
SL-2DVP
SLP90
ASSEMBLY
HORIZONTAL TERMINATION CAP
Heatilator • ECLIPSE-32, ECLIPSE-36 Installation Manual • 2297-984 Rev. B • 6/15
Effective Length
5-1/2 in.
5-3/4 to 8-3/8 in.
140 mm
146 to 213 mm
DVP-HRC-ZC-SS NOT APPROVED FOR ALL UNITS.
WARNING
Effective Length
5-3/4 to 8-3/8 in.
5-1/2 in.
146 to 213 mm
140 mm
87°
SLP-HRC-SS
SLP-HRC-ZC-SS
DVP-TB1
DVP-TB1
DVP-TB1
8-3/8 in.
213 mm
87°
10-1/2 in.
267 mm
10-7/8 in.
276 mm
8-3/8 in.
213 mm
10-1/2 in.
267 mm
10-7/8 in.
276 mm
53