Heatilator ECLIPSE Series Owner's Manual
Heatilator ECLIPSE Series Owner's Manual

Heatilator ECLIPSE Series Owner's Manual

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions regarding installation, operation or service.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Owner's Manual
Care and Operation
Heatilator • ECLIPSE-32, ECLIPSE-36 Owner's Manual • 2297-985 Rev. L • 1/19
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See appliance installation manual for additional
Commonwealth of Massachusetts requirements.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECLIPSE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Heatilator ECLIPSE Series

  • Page 1 See appliance installation manual for additional Commonwealth of Massachusetts requirements. gases, unless a certified kit is used. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 2: Welcome

    00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 3: Table Of Contents

    C. Contact Information ......25  = Contains updated information. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 4: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 6: Product Specific Information

    Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 7: Important Safety And Operating Information

    • Install a switch lock or a wall/remote control with child protection lockout feature. Figure 3.1 Clear Space • Keep remote controls out of reach of children. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 8: General Operating Parts

    30 in. 132°F 24 in. 18 in. 142°F 12 in. 6 in. MEASUREMENTS FROM TOP EDGE OF THE OPENING APPLIANCE FRONT Figure 3.3. Maximum Wall Surface Temperatures Above Appliance Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 9 “C” dimension taken from the top of the hood or fireplace opening. Sugges ons on how to further reduce TV temperatures: Increase “A” dimension. Increase “C” dimension, however, increasing “B” dimension beyond maximum recommended typically results in higher temperatures. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 10: Before Lighting Appliance

    • Ensure that the glass is sealed and in the proper position and that the integral barrier is in place. WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fireplace with fixed glass assembly removed. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 11: Lighting Instructions (Ipi)

    Propane Installation code, CSA B149.1. P65Warnings.ca.gov. For additional information on operating your Keep burner and control compartment clean. See installation and operating instructions accompanying appliance. refer to www.hearthnhome.com. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 12: Appliance Break-In

    Turn the knob clockwise to increase the fan speed and counterclockwise to decrease the fan speed. CONTROL VALVE LOCATION CAVITY Figure 3.4 Control Cavity/Valve Location Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 13: Operation During A Power Outage

    Section 3.G. Detailed instructions are in- backup including remote control, fan, lights, or any other cluded with the fan kit. auxiliary functions that require household 110-120 VAC power. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 14: Maintenance And Service

    See Figure 4.1. • Inspect and operate all glass latches to ensure they move freely and no obstructions are present. • Reinstall decorative front. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 15 If not using your fireplace for an extended period of time (summer months, vacations/trips, etc), to prevent unin- tended operation: • Remove batteries from remote controls. • Unplug 3 volt adapter plug on IPI models. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 16: Maintenance Tasks - Qualified Service Technician

    • Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. Figure 4.2 IPI Pilot Flame Patterns Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 17: Frequently Asked Questions And Troubleshooting

    Refer to (battery backup) Section 3 for more details. Contact your dealer for additional information regarding operation and troubleshooting. Visit www.heatilator.com to locate a dealer. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 18: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. D. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 19 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fine. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 20: Reference Materials

    Media Kits are available for use with the ECLIPSE-32 and ECLIPSE-36 models. Install media according to the in- structions included with the kit. WARNING! Choking Hazard! Keep media out of reach of children. Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...
  • Page 21: Service Parts

    6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7074035, 7098269, 7258116, 7322819, 7470729, 7726300, 8147240, 9625149 or other U.S. and foreign patents pending. 2000-945D Printed in U.S.A. - Copyright 2019 Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. L • 1/19...