Troubleshooting; Video Troubleshooting - HIS -ML19- *** G User Manual

19" panel mount industrial monitor
Table of Contents

Advertisement

Video Troubleshooting
IMPORTANT!
If using a KVM extender, first try to resolve any problems using the solutions listed 
below�  If the problem still exists, try bypassing the KVM extender�  If this fixes the 
problem and allows the monitor to work properly, then the KVM extender is the 
source of the problem�  Please refer to the troubleshooting section of the KVM 
extender manual or contact Hope Industrial Systems for additional assistance�
Symptom
No image on 
the screen and 
control's Power 
Indicator light is 
not lit
No image on 
the screen and 
control's Power 
Indicator light is 
lit orange
Screen image is 
dim

Troubleshooting

Causes
Monitor is not powered on�
The "Auto Power Off"
function is enabled�
Video cable is not plugged in
correctly�
PC is in Power Saving
mode�
PC is not powered on�
PC is not sending signal�
Brightness and/or contrast
settings are not set properly�
Solutions
Press the Power button on the
monitor and make sure the Power
Indicator light is lit blue�
Check power connections at the
monitor and power source�
For DC models, check the connector
polarity and ensure input voltage is
9�6 to 36�6 VDC�
Disable this setting by unchecking the box
for the "Auto Power Off" function in the
OSD's "Setup" menu�
Check the video cable connection at the
monitor, PC, and/or KVM extender�
Power Saving mode can usually be exited
by moving the mouse�
Ensure PC is powered on�
Connect the PC to another known working
monitor to check the PC source signal�
Adjust the monitor's brightness and
contrast settings in the OSD's "Contrast/
Brightness" menu�
ML19G User Manual, January 2015