Installation Instructions; Step 1: Prepare For Installation - HIS -ML19- *** G User Manual

19" panel mount industrial monitor
Table of Contents

Advertisement

Installation Instructions

Step 1:  Prepare for Installation
IMPORTANT!
Perform the following steps BEFORE installation of the monitor into the panel�
1� Ensure that sufficient power is available�
2� Ensure that sufficient space is available to allow for proper air flow into and out of the
unit�
3� Ensure that the air temperature around the unit (top and bottom) will not exceed the
rated specifications of the unit.
f The maximum rated temperature for the HIS-ML19 is 50°C (122°F)�
!
f Remember  that  heat  rises  –  the  temperature  at  the  top  of  the 
cabinet  will  be  much  hotter  than  at  the  bottom  if  air  inside  the 
enclosure is not actively circulating�  Even in a sealed enclosure, 
use of a circulation fan can greatly reduce temperature�
f Also,  remember  that  even  though  this  product  is  designed  to 
operate at 50°C, the life span of any electronic device is shortened 
when it is consistently operated at high temperatures�  Therefore, 
it is wise to take steps to keep the temperature of the ambient air 
around the unit as low as possible�
4� Ensure that the ambient humidity of the air around the unit does not exceed the
specifications of the unit.
f The  maximum  rated  humidity  for  the  HIS-ML19  is  90%                                               
non-condensing�
  ML19G User Manual, January 2015