Notes
• You cannot specify such section that exceeds the file
size.
• If the file name character string contains one or more
spaces, this command cannot be used. Use the SITE
REPFL command.
Command syntax: SITE REPF <SP> <path-name> <SP>
<start frame> <SP> <transfer size> <CRLF>
<start frame> specifies the offset of the video frame to start
transfer with respect to the top of the file ("0" for the top
frame).
<transfer size> specifies the number of video frames to
transfer (specifies "0" to perform transfer of data up to the
end of the file).
Input example: SITE REPF Clip/C0001.MXF 5 150
Transfer C0001.MXF. For the body, however,
data from sixth frame through 150th frame is only
transferred.
SITE REPFL
Transfers an MXF file existing in the specified path of this
unit to the current directory of the computer. This
command allows you to specify a section of the body of
MXF file (data comprised of video and audio) and transfer
that section only.
Note
You cannot specify such section that exceeds the file size.
Command syntax: SITE REPFL <SP> "<path-name>"
<SP> <start frame> <SP> <transfer size> <CRLF>
<path-name> specifies the file path name by enclosing it in
double quotation marks (" ").
<start frame> specifies the offset of the video frame to start
transfer with respect to the top of the file ("0" for the top
frame).
<transfer size> specifies the number of video frames to
transfer (specifies "0" to perform transfer of data up to the
end of the file).
Input example: SITE REPFL "Clip/sakura 0001.MXF" 5 150
Transfer sakura 0001.MXF. For the body,
however, data from sixth frame through 150th
frame is only transferred.

CIFS File Operations

You can perform file operations using the Common
Internet File System (CIFS) between this unit and the
computer.
Preparations
See "Preparations" under "FTP File Operations"
(page 69).

Making CIFS connections

CIFS connections between this unit and a Windows
computer can be made with either of the following.
• Use Windows Explorer to map this unit as a network
drive
• Refer to this unit directly from Windows Explorer
The following describes the procedure for using Windows
Explorer to map this unit as a network drive.
1
Start Windows Explorer.
2
In the Tools menu, select "Map Network Drive...".
The Map Network Drive dialog appears.
3
Enter "\\<IP address>\xds\" in the "Folder" field.
For example, if the IP address of this unit is set to
"192.168.001.010", enter "\\192.168.1.10\xds\".
4
Click on "Connect using a different name".
The Connect As... dialog appears.
5
Enter the user name "admin" and the password, and
click OK.
The password is set to the model name ("xds-pd1000"
or "xds-pd2000") when the unit is shipped from the
factory.
6
Click Finish.
The network drive allocation is complete when the
password is verified.
To break the connections
In Windows Explorer, select the network drive and right-
click it, then click "Disconnect".
73