5-3. VIDEO SECTION ADJUSTMENTS
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1.
Equipment Required
1)
TV monitor
2)
Oscilloscope (dual-phenomenon, band above 30 MHz with
delay mode) (Unless specified otherwise, use a 10 : 1 probe.)
3)
Frequency counter
4)
Pattern generator with video output terminal.
5)
Digital voltmeter
6)
Audio generator
7)
Audio level meter
8)
Audio distortion meter
9)
Audio attenuator
10) Regulated power supply
11) Alignment tapes
• Tracking standard (XH2-1)
Parts code: 8-967-997-01
• SW/OL standard (XH2-3)
Parts code: 8-967-997-11
• Audio operation check for PAL (XH5-3P)
Parts code: 8-967-997-55
• System operation check for PAL (XH5-5P)
Parts code: 8-967-997-66
12) Adjustment remote commander (J-6082-053-B)
13) CPC-8 jig (J-6082-388-A)
14) IR receiver jig (J-6082-383-A)
15) Extension cable (100P, 0.5mm)(J-6082-352-A)(Note)
For extension between the MS-070 board (CN1901) and the
VC-260 board (CN011).
Note: DCR-TRV17E model only.
5-35