Flange Back Check - Sony DCR-TRV15E Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-TRV15E:
Table of Contents

Advertisement

5. Flange Back Check

Subject
Siemens star
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE end.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Note: When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 6, address: 04, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Checking method:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Shoot the Siemens star with the zoom TELE end.
4)
Turn on the auto focus.
5)
Check that the lens is focused (Note).
6)
Select page: 6, address: 21, and set data: 10.
7)
Shoot the Siemens star with the zoom WIDE end.
8)
Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 6, address: 04, and set data: 00.
Odd: Focused
Even: Unfocused
5-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv17eDcr-trv15Dcr-trv17

Table of Contents