1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of "VIDEO SYSTEM ADJUSTMENT" are
satisfied.
1. 36MHz Origin Oscillation Adjustment
(VC-260 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin qh of IC303
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
12
Specified Value
f=18000000 ± 90Hz
Adjusting method:
Order Page Address Data
1
0
01
01
2
F
12
3
F
12
4
0
01
00
24 13
25
12
36
1
37 48
IC303
VC-260 board
Fig. 5-1-6.
Procedure
Set the data.
Change the data and set the
frequency (f) to the specified
value.
Press PAUSE button.
Set the data.
2. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value 1
Specified Value 2
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
1
0
01
2
6
94
3
6
95
4
6
01
5
6
02
6
6
01
Note2: The adjustment data will be automatically input to page: F, address:
17, 18, 19.
Checking method:
Order Page Address Data
1
6
04
2
6
01
3
1
4
6
01
5
1
Processing after Completing Adjustments:
Order Page Address Data
1
6
94
2
6
95
3
6
01
4
6
04
5
0
01
5-16
RadarW
RadarW
RadarW
Not required
Display data of page 1 (Note1)
Adjustment remote commander
F
17, 18, 19
14 to 18
85 to 89
IRIS display data
Procedure
01
Set the data.
16
Set the data.
87
Set the data.
6D
Set the data, and press PAUSE
button.
Check that the data changes to "01".
(Note2)
00
Set the data, and press PAUSE
button.
Procedure
03
Set the data.
01
Set the data, and press PAUSE
button.
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
03
Set the data, and press PAUSE
button.
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Procedure
00
Set the data.
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.