MULTIQUIP GA3.6HR Operating Manual page 40

Honda gx240rt2edn2 gasoline engine
Hide thumbs Also See for GA3.6HR:
Table of Contents

Advertisement

OPERATING INSTRUCTIONS
1. Before starting check the oil and fuel level.
2. Switch the circuit breaker to the "OFF" position.
3. Open the fuel valve.
4. Pull the choke knob.
5. Turn the operation switch to the "ON" position.
1
6. Pull the recoil starter.
7. After the engine starts, gradually push in the choke knob.
8. Run the generator for 3-5 minutes without load.
9. Check for any abnormal noise or smell.
10.Switch the circuit breaker to the "ON" position.
11.When stopping, cut-off the load and allow the unit
to cool for 2-3 minutes before stopping engine.
12.Turn the operation switch to the "OFF" position.
13. After the engine completely stops, close the fuel valve.
WARNING
To avoid injury,
you MUST read
and understand
operator's manual
before using this
7
machine.
This machine to
be operated by
qualified
personnel only.
Ask for training
as needed.
AIR CLEANER MAINTENANCE
CLEAN ELEMENT EVERY 50 HOURS (EVERY
10
10 HOURS UNDER DUSTY CONDITIONS.
WASH IN HIGH FLASH-POINT SOLEVENT
SQUEEZE DRY, THE DIP IN CLEAN ENGINE
OIL AND SQUEEZE OUT EXCESS OIL.
pAgE 40 — ga3.6HR 60 hz gENERATOR• OpERATiON ANd pARTs mANuAl — REv. #0 (09/17/14)
GA3.6HR — NAmEPlATE AND DECAlS ASSy.
A92120010
DANGER
CAUTION
OPERATE AT
3600 RPM ONLY
Do not touch output terminals or
internal wiring while unit is operating.
(
FULL THROTTLE
Turn off power before servicing.
S-4985
Only qualified personnel should
ELECTRICAL
DAMAGE MAY RESULT IF
SHOCK
install, use or service this
OPERATED AT LOWER SPEEDS
HAZARD
equipment.
WARNING
WARNING
B e f o r e c o n n e c t i n g t h i s
Only operate machine in well ventilated
g e n e r a t o r t o a n y b u i l d i n g ' s
areas.
e l e c t r i c a l s y s t e m , a l i c e n s e d
DO NOT inhale exhaust gases.
e l e c t r i c i a n m u s t i n s t a l l a n
i s o l a t i o n ( t r a n s f e r ) s w i t c h .
Only qualified personnel should
S-4984
S e r i o u s i n j u r y o r d e a t h m a y
install, use or service this
Only qualified personnel should
DANGEROUS
install, use or service this
r e s u l t w i t h o u t t h i s t r a n s f e r
equipment.
GAS
equipment.
s w i t c h .
FUEL COCK
ON
8
ON
S-3704
GA-3.6HR
120V
120V
20A
20A
Using a generator indoors CAN KILL YOU IN MINUTES.
Utilser un générateur à l' intérieur VOUS TUERA EN QUELQÙES MINUTES.
Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
Les gaz d' échappement contiennent du monoxyde de carbon, un gaz toxique
invisible et inodore.
NEVER use in enclosed or partially
enclosed areas.
Utilisation INTERDITE dans un
espace clos ou partiellement clos.
WARNING
Operation of this equipment may create
sparks that can start fires around dry
vegetation.
A spark arrestor may be required.
The operator should contact local fire
agencies for laws or regulation relating
to fire prevention requirements.
M90420000
DANGER
THE POSSIBILITY EXISTS OF ELECTROCUTION IF
GENERATOR/WELDER IS NOT PROPERLY GROUNDED.
ALWAYS CONNECT EARTH GROUND (GROUND
ROD) TO GENERATOR GROUND POINT.
0N
6000
OFF
V
120
OFF
ON
IDLE
CONTROL
120V
OFF
21A
SWITCH
OPERATION
GROUND
AC CIRCUIT
BREAKER
20A
GA-6H
120V/240V
FULL POWER
120/240V
30A
30A
120V
SWITCH
20A
SCREW
GROUND
CABLE
#8 MINIMUM
GROUND ROD
FOR EARTH
GROUND
CONNECT TO
BUILDING
GROUND
IF REQUIRED
FOR FURTHER GROUNDING
8 FT. MINIMUM
INSTRUCTIONS, READ MANUAL
REFERENCE
NEC 250-52(C)
D9531100104
)
9
A91110010
L O
P I N
P/N A351000010
12
ON
0N
OFF
OFF
IDLE
AC VOLTMETER
CONTROL
OPERATION
SWITCH
120V
AC CIRCUIT BREAKER
GFCI PROTECTED
240/120V
FULL POWER
SWITCH
120V
120V
120/240V
20A
30A
30A
A31120120
DANGER
2
GAC-2.2H
11250AV
120
V
NEUTRAL BONDED TO FRAME
GAC-2.2H
11250AV
NEUTRAL BONDED TO FRAME
211052
Honda Engines
POWERED by
E LDAU M
ISS A
AS
LNAE UCTARREC M
P
IRR
TE
C
IO N U
A
R
EL R
MAOSTSEEU A
KA
E
211052
POWERED by
Honda Engines
V
120
LNAE UCTARREC M
IRR
AS
ISS A
A
E LDAU M
C
KA
EL R
MAOSTSEEU A
R
GR TPERRIS
REE DE
CC
R
ACR
NUU
TIT
RER
P TB
CA ID
IU N ER
P
GR TPERRIS
REE DE
TE
R
CC
NUU
ACR
TIT
IO N U
P
RER
P TB
E
P
CA ID
IU N ER
POWERED by
Honda Engines
GAC-2.2H
11250AV
120
V
LNAE UCTARREC M
AS
NEUTRAL BONDED TO FRAME
ISS A
E LDAU M
MAOSTSEEU A
R
211052
GR TPERRIS
REE DE
P
P TB
RER
NUU
A
IRR
TE
IO N U
ACR
TIT
C
R
CC
EL R
E
KA
CA ID
P
IU N ER
ONLY use outdoors and away from
open windows, doors, and vents.
Utilisation UNIQUEMENT à l' extér leur
portes et trous d' aération
A90400001
3
MODEL
SERIAL NO.
4
5
C K
11
13
6
S-1123
3.6kW

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GA3.6HR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents