*80 Device Programming Menu Mode
The "STOP" programming determines when and under what conditions the device will be de-
STOP
activated. The following options are available:
Upon Restore of a Zone List
Restore Zone List: If a "ZONE LIST" is used as the "Stop" event, the device will de-activate
when all the zones in that list restore from a previous fault, trouble, or alarm condition. This will
occur regardless of what is programmed to "START" the device; therefore, a "RESTORE ZONE
LIST" would normally only be used when a "ZONE LIST" is used to start the device.
Upon a Zone Type or System Operation
Zone Type/System Operation: Instead of using a "RESTORE ZONE LIST," a specific zone
(response) type or system operation action can be selected to de-activate the device.
If a specific "ZONE TYPE" is chosen, any zone of that response type that restores from a
previous alarm, trouble, or fault condition will cause the device to de-activate.
If a "SYSTEM OPERATION" is chosen, that operation will cause the device to de-activate.
During normal system operation, any devices may be manually started by keypad entry of: Code* + [#] + 4 + "n;"
or manually stopped by keypad entry of: Code* + [#] + 7 + "n," where "n" = the device number to be controlled.
* Code is required for devices 7 and 8. For devices 1-6, code is not required. See User Manual for more information.
Programming Powerline Carrier Devices
While in program mode, press
devices used in the system. Refer to the output device table for
programming output devices.
NOTE: The House ID of the Powerline Carrier Devices must be entered in data field *25.
The prompts for *80 are as follows:
80
Powerline Carrier Device Programming Main Menu prompt
A 01
Device Number ------------------------for entering the device number
b
Device Action --------------------------for defining the action the device will perform when active
C
Start Event Type -----------------------for assigning the event type to start the action
d
Start Zone List -------------------------for assigning the zone list to start the action
E
Start Zone Type------------------------for assigning the zone type to start the action
F
Stop Zone List -------------------------for assigning the zone list to stop the action
1A
Stop Zone Type ------------------------for assigning the zone type to stop the action
The following explains these prompts in detail. The left two columns identify the prompts and list the available
entries. The right-most column provides a further explanation of the entries.
NOTE: Entry of a number other than one specified will give unpredictable results.
80 to enter Output Device Menu Mode. This mode is used to program all output
*
*
80 on the separate programming form when
–28–