Contec 955 Series User Manual page 16

Ipc series
Table of Contents

Advertisement

Table 2.2. Installation Environment Requirements
Model
Operating temperature *7
Storage temperature
Operating humidity
Floating dust particles
Corrosive gas
Line noise
Noise
Static
resistance
electricity
resistance
Vibration
Sweep
resistance
resistance
Impact resistance
Grounding
*7: For more details on this, please refer to chapter 3, "Installation Requirements".
*8: When using the AC-DC power supply.
PT-955LXC-DC5311 User's manual
< When using 100BASE-TX/10BASE-T >
0 - 50 ° C
(When the total current for the USB port power supply capacity is 1.5 A or higher :
0 - 45°C)
< When using 1000BASE-T >
0 - 45 ° C
(When the total current for the USB port power supply capacity is 1.5 A or higher :
0 - 40°C)
-10 - 60 ° C
10 - 90%RH (No condensation)
Not to be excessive
None
AC line / ± 2kV *8,
Signal line/ ± 1kV (IEC61000-4-4 Level 3, EN61000-4-4 Level 3)
Contact discharge / ± 4kV (IEC61000-4-2 Level 2, EN61000-4-2 Level 2),
Atmospheric discharge / ± 8kV (IEC61000-4-2 Level 3, EN61000-4-2 Level 3)
10 - 57Hz / semi-amplitude 0.15 mm 57 - 150Hz / 2.0G,
40 min. each in x, y, and z directions (JIS C60068-2-6-compliant, IEC60068-2-6-compliant)
10G, half-sine shock for 11 ms in x, y, and z directions
(JIS C60068-2-27-compliant, IEC60068-2-27-compliant)
Class D grounding, SG-FG / continuity
PT-955LXC-DC5311
2. System Reference
9

Advertisement

Table of Contents
loading

Table of Contents