Cabling the
Provider Unit
Powering On the
Provider Unit
To cable the Provider unit, perform the following steps:
1. Connect the Ethernet cable from the Ethernet port to the Service
Provider box (ISP) in your wiring closet, as shown in Figure 16.
Figure 16. Connecting AT-MC606 Ethernet Port to an Internet Service
2. Connect a coaxial cable from the VDSL Line port to the wall/interior
coaxial cable, as shown in Figure 10 on page 36, so that the Provider
unit can communicate with the Subscriber unit.
If you have rack mounted the AT-MC606 Provider unit in an AT-MCR12
rackmount chassis, the chassis must be powered on which provides
power to the AT-MC606.
Warning
The QUALIFIED SERVICE PERSONNEL must verify that the
AT-MCR12 rackmount chassis power cord is connected to the
socket provided with the ground conductor.
If the power cord is not connected, the QUALIFIED SERVICE
PERSONNEL must install a permanent ground connection using the
bond stud on the rear panel of the AT-MCR12 rackmount chassis.
For detailed information on how to power on the AT-MCR12 rackmount
chassis, refer to the AT-MCR12 Media Converter Rackmount Chassis
Installation Manual.
If you have installed a stand alone AT-MC606 Provider unit, power on the
unit using the power adapter provided, as shown in Figure 11 on page 37.
AT-MC606 VDSL Network Extender Installation Guide
Internet
M C R 1 2
Provider
1940
41