  • Page 1 ◆ Installation User’s Guide PN 613-50538-00 Rev B Extended ® Ethernet AT-MC601 AT-MC602...
  • Page 2 Copyright © 2004 Allied Telesyn, Inc. www.alliedtelesyn.com All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Microsoft is a registered trademark of Microsoft Corporation, Netscape Navigator is a registered trademark of Netscape Communications Corporation.
  • Page 3: Electrical Safety And Emission Statement

    Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. U.S. Federal Communications Commission Allied Telesyn, Inc. (www.alliedtelesyn.com) Extended Ethernet AT-MC601, AT-MC602 FCC Part 68 Product Identifier Industry Canada...
  • Page 4 Obs! Bilaga C innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser till Bilaga C för att läsa det översatta säkerhetsmeddelandet på ditt språk. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Class A, FCC Part 15 Class A, C-TICK...
  • Page 5: Table Of Contents

    Contents Electrical Safety and Emission Statement ... 3 Preface ... 7 How This Guide is Organized ... 7 Document Conventions ... 8 Contacting Allied Telesyn Technical Support ... 9 Online Support ... 9 E-mail and Telephone Support ... 9 Returning Products ... 9 For Sales or Corporate Information ...
  • Page 6 Default Configuration Settings ...51 Appendix B Technical Specifications ...52 Physical Specifications ...52 Environmental Specifications ...52 Power Specifications ...52 Safety and Electromagnetic Compatibility Certifications ...53 Appendix C Translated Electrical Safety and Emission Information ...54 AT-MC601 and AT-MC602 Installation and User’s Guide...
  • Page 7: Preface

    Preface This guide contains instructions on how to install and configure the AT-MC601 and AT-MC602 Extended Ethernet units. How This Guide is Organized This manual contains the following chapters and appendices: Chapter 1, Product Description, describes the features and components of the network extenders.
  • Page 8: Document Conventions

    Warnings inform you that performing or omitting a specific action may result in bodily injury. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. AT-MC601 and AT-MC602 Installation and User’s Guide...
  • Page 9: Contacting Allied Telesyn Technical Support

    FTP server from your workstation’s command prompt, you will need FTP client software and you will be asked to log in to the server. Enter ‘anonymous’ as the user name and your email address for the password. AT-MC601 and AT-MC602 Installation and User’s Guide...
  • Page 10: Product Description

    Chapter 1 Product Description The AT-MC601, AT-MC602 Extended Ethernet products are designed to transmit data at very high speeds over unshielded pairs of copper wires using VDSL technology on your existing telephone line. Summary of Features ❑ VDSL (Very high-bit-rate Digital Subscriber) Line port ❑...
  • Page 11: Overview

    Each AT-MC602 or provider unit would be located in the building wiring closet. The AT-MC601 Extended Ethernet unit can be used as a desktop or wallmount device while the AT-MC602 unit must be installed in an AT-MCR12 rackmount chassis.
  • Page 12: Location Of Components

    Location of Components Figure 2 illustrates the front panels of the AT-MC601 and AT-MC602 network extenders. Ethernet Status LEDs Ethernet Status LEDs Figure 3 illustrates the rear panel of the AT-MC601 and AT-MC602 network extenders. AT-MC601 and AT-MC602 Installation and User’s Guide...
  • Page 13: Hardware Features

    VDSL Line Port The VDSL Line port allows you to connect the AT-MC601 Subscriber unit to a telephone jack (wall outlet) and the AT-MC602 Provider unit to the inside phone line at the wiring closet. The two units need to be within 1,200 meters of each other in order for the port to operate properly.
  • Page 14: Pstn Port

    PSTN Port The PSTN port allows you to connect the AT-MC601 Subscriber unit to a telephone and the AT-MC602 Provider unit to the outside telco box. This port features an RJ-11 connector. Table 2 lists the RJ-11 port pinouts and their assignments.
  • Page 15 The AT-MC601 and AT-MC602 network extenders can operate in either half- or full-duplex mode. The network extender can operate with end- nodes capable of either half-duplex, full-duplex, or that can Auto- Negotiate the duplex mode.
  • Page 16: Status Leds

    The AT-MC601 and AT-MC602 network extenders feature the following status LEDs: ❑ Power ❑ Ethernet: link and activity ❑ VDSL Line: link and error Table 4 defines the LEDs for the AT-MC601 and AT-MC602 network extenders. 10/100Base-TX Port LINK LINE Port LINK AT-MC601 and AT-MC602 Installation and User’s Guide...
  • Page 17: Mgmt Port

    PC-compatible computer for configuration using the provided management cable. Management The management cable included with the AT-MC602 Provider unit features a 9-pin RS-232 connector to attach to your computer and an Cable 8-pin DIN connector to attach to the network extender.
  • Page 18: Ac Power Supply Input Port

    12V DC at 1A. Note The power adapter mentioned above is not required to be used with the AT-MC602 Provider unit because the AT-MC602 Provider unit can only be installed in the AT-MCR12 chassis AT-MC601 and AT-MC602 Installation and User’s Guide...
  • Page 19: Software Features

    Software Features The AT-S57 software used to configure the AT-MC601 and AT-MC602 network extenders has the following features: ❑ Determine the VDSL link status ❑ Set the upstream and downstream data transfer rates ❑ Monitor the status of the VDSL parameters on both the local and ❑...
  • Page 20: Chapter 2 Installation

    The installation process is described in the following sections: ❑ Installation Safety Precautions ❑ Selecting a Site for the Network Extender ❑ Required Cables ❑ Unpacking the Network Extender ❑ Installing the AT-MC601 Subscriber Unit ❑ Installing the AT-MC602 Provider Unit ❑ Warranty Registration...
  • Page 21: Installation Safety Precautions

    Caution Operating Temperature: This product is designed for a maximum ambient temperature of 40°C. Caution All Countries: Install this product in accordance with local and national electric codes. AT-MC601 and AT-MC602 Installation and User’s Guide...
  • Page 22: Additional Compliance Warning Statements

    Additional Additional telecommunication-related compliance warning statements used with the AT-MC601 and AT-MC602 Extended Ethernet units are Compliance listed below: Warning Statements Warning When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electronic shock and injury to persons, including the following: 1.
  • Page 23: Selecting A Site For The Network Extender

    Observe the following requirements when choosing a site for your network extender: ❑ Make sure that the AT-MC602 Provider unit is installed in the ❑ If you plan to install the AT-MCR12 in an equipment rack, check to ❑ If you are installing the network extender on a table, be sure that ❑...
  • Page 24: Cables Not Included

    Cables Not Included The AT-MC601 and AT-MC602 network extenders require the three cables described in Table 6 below. These cables are not included with the network extenders. Port Ethernet PSTN VDSL Line AT-MC601 and AT-MC602 Installation and User’s Guide Table 6 Cables...
  • Page 25: Unpacking The Network Extender

    ❑ Four protective feet ❑ Two Phillips-head screws for wall-mounting ❑ Two plastic anchors for wall-mounting ❑ One power adapter ❑ One management cable (provided for AT-MC602 model only) ❑ Documentation and configuration software CD ❑ Warranty and registration card Note You must use the original shipping material if you need to return the unit to Allied Telesyn.
  • Page 26: Installing The At-Mc601 Subscriber Unit

    2. Attach the four protective feet (provided) to each corner of the bottom of the unit, as illustrated in Figure 6. PSTN LINK LINE Figure 6 Attaching Protective Feet to the Subscriber Unit AT-MC601 and AT-MC602 Installation and User’s Guide AT-MC601 ETHERNET EXTENDED VDSL MGMT...
  • Page 27: Wall-Mounting The Subscriber Unit

    Figure 7 Installing the Screws and Plastic Anchors Onto The Wall 4. Position the switch onto the wall screws so that the ports are facing the ceiling, as shown in Figure 8. AT-MC601 and AT-MC602 Installation and User’s Guide Figure 8 Positioning The Switch Onto The Wall Screws...
  • Page 28: Cabling The Subscriber Unit

    Ethernet port on the computer, as shown in Figure 9. 2. Then, connect a telephone line cable from the PSTN port to the telephone, as shown in Figure 10. AT-MC601 and AT-MC602 Installation and User’s Guide 10 Ba se 10 0B as...
  • Page 29: Powering On The Subscriber Unit

    Power on the Subscriber unit using the power adapter provided, as shown in Figure 12. the Subscriber Unit AT-MC601 and AT-MC602 Installation and User’s Guide Wall/Interior Phone Line Figure 11 VDSL Line to Wall/Interior Phone Line 1 2 V D...
  • Page 30: Installing The At-Mc602 Provider Unit

    Installing the AT-MC602 Provider Unit The AT-MC602 Provider unit can only be installed in an AT-MCR12 rackmount chassis. To install the Provider unit in an AT-MCR12 rackmount chassis, perform the following steps: 1. Attach the unit to one of the sliders that will hold the unit in the chassis, as shown in Figure 13.
  • Page 31 AT-MC601 and AT-MC602 Installation and User’s Guide 2. Then, set the slider in the chassis, as shown in Figure 14. PO W ER Figure 14 Rack Mount - Set in Rack...
  • Page 32: Cabling The Provider Unit

    Provider box in your wiring closet, as shown in Figure 15. 2. Then, connect a telephone line cable from the PSTN port to the outside telco box, as shown in Figure 16. AT-MC601 and AT-MC602 Installation and User’s Guide Internet Service...
  • Page 33: Powering On The Provider Unit

    The procedure for connecting the management cable is described in ”Cabling Preparations” on page 36. Powering On Powering on the AT-MC602 Provider Unit requires that the host equipment, AT-MCR12 rackmount chassis, is powered on as well. For the Provider detailed information on how to power on the AT-MCR12 unit, refer to Unit the AT-MCR12 Media Converter Rackmount Chassis Installation Manual.
  • Page 34: Warranty Registration

    AT-MC601 and AT-MC602 Installation and User’s Guide Warranty Registration When you have finished installing the network extender, register your product by completing the enclosed warranty card and mailing it to Allied Telesyn.
  • Page 35: Chapter 3 Configuration

    To actively configure a network extender by changing or adjusting its operating parameters, you must access the AT-S57 software while connected to the AT-MC602 Provider unit. The AT-S57 software has a menu interface that makes it very easy to use.
  • Page 36: Starting A Configuration Session

    Starting a Configuration Session Downloading In order to configure and manage your AT-MC601 and AT-MC602 VDSL network extenders, you need to download a copy of the configuration Software software onto the computers you will use to manage the units. The AT-...
  • Page 37: Opening The Configuration Software

    Select the computer port you are using from the pull-down menu on the AT-MC60x Configurator pop-up and click OK. If you are connected to the AT-MC602 Provider unit and want to configure the network extenders, continue with the next section, ”Configuring the Provider Unit”...
  • Page 38: Configuring The Provider Unit

    AT-MC601 and AT-MC602 Installation and User’s Guide Configuring the Provider Unit After performing the procedure described in the previous section, ”Starting a Configuration Session” on page 36, if you are connected to the Provider unit, the AT- MC60x Configurator menu will appear. The...
  • Page 39 (This report will keep repeating with progressively higher upstream and downstream values until the set rate or the highest possible rate has been achieved.) Saving config on EEPROM - S Side Saving config on EEPROM - P Side Done AT-MC601 and AT-MC602 Installation and User’s Guide...
  • Page 40: Vdsl Status

    Use the About button to display the version number of the AT-S57 configuration software. VDSL Status To view the VDSL Status screen, click on the VDSL Status tab at the top of the menu. AT-MC601 and AT-MC602 Installation and User’s Guide Figure 22 Configuration Saved...
  • Page 41 AT-MC601 and AT-MC602 Installation and User’s Guide The VDSL Status screen is displayed in Figure 23. Figure 23 VDSL Status The parameters on the VDSL Status screen are described below. These parameters are for viewing and monitoring purposes only. They cannot be changed manually.
  • Page 42: Ethernet Status

    AT-MC601 and AT-MC602 Installation and User’s Guide Reduced Constellation Link A lesser QAM constellation, causing reduced line rates. If the full constellation rate cannot be achieved because the received SNR is too low, then a reduced constellation link can be established and the software can automatically configure the Subscriber unit parameters.
  • Page 43 AT-MC601 and AT-MC602 Installation and User’s Guide The Ethernet Status screen is displayed in Figure 24. Figure 24 Ethernet Status The parameters on the Ethernet Status screen are described below. TxRx Counters The data fields in this section indicate the number and type of frames that have been transmitted and received via the Ethernet link.
  • Page 44 AT-MC601 and AT-MC602 Installation and User’s Guide Stop/Start This button allows you to pause counting. When you press Stop, the counters remain at their present values. When you press Start, the counters continue adding to the values already recorded by the software.
  • Page 45: Configuring The Subscriber Unit

    AT-MC601 and AT-MC602 Installation and User’s Guide Configuring the Subscriber Unit In rare instances, you may need to use the configuration software on the Subscriber unit to attempt link recovery. If the configuration software detects a problem with the Subscriber unit while you are connected to the Provider unit, it will prompt you to use the software on the Subscriber unit by displaying a pop-up error message.
  • Page 46 AT-MC601 and AT-MC602 Installation and User’s Guide of time, a timeout will occur. After a timeout, the default configuration parameters will be used to establish a link with the highest possible speed. The default configuration parameters start at 0.94 Mbps upstream and downstream with negotiation set from Low ->...
  • Page 47: Chapter 4 Troubleshooting

    Chapter 4 Troubleshooting This chapter contains information on how to troubleshoot the AT-MC601 and AT-MC602 network extenders in the event a problem occurs. LEDs Check the PWR LED on the front of the network extender. If the LED is OFF, indicating that the network extender is not receiving power, do the...
  • Page 48: Error Messages

    ,” as shown in Figure 27 Figure 27 No Answer Error Message Figure 28 Communication Error Message AT-MC601 and AT-MC602 Installation and User’s Guide ,” as shown in Figure 28...
  • Page 49 Please run this program on S side to set it in Install mode. If S side is already in install mode then configuration can not be achieved,” as shown in Figure 29. Figure 29 Run on S Side Error Message AT-MC601 and AT-MC602 Installation and User’s Guide ”...
  • Page 50 Syntax error in configuration file ❑ “ Configuration cannot be achieved These last three error messages indicate a problem with the configuration software. Try re-loading the software onto your computer. AT-MC601 and AT-MC602 Installation and User’s Guide ” ” ”...
  • Page 51: Default Configuration Settings

    Appendix A Default Configuration Settings This appendix lists the AT-MC601 and AT-MC602 default settings. Setting Provider Parameters Monitored Speeds Upstream Max Upstream Min Downstream Max Downstream Min Flow Low to High Ethernet Port Duplex Mode Speed MDI/MDI-X Link Recovery Subscriber Unit Mode...
  • Page 52: Technical Specifications

    Appendix B Technical Specifications Physical Specifications Dimensions: Weight: Recommended Minimum Clearance on All Sides: Environmental Specifications Operating Temperature: Storage Temperature: Operating Humidity: Storage Humidity: Operating Altitude: Non-operating Altitude: Power Specifications Power Consumption: Input Supply Current: Input Supply Voltage: (W x D x H) 109 mm x 95 mm x 25 mm (4.29 in.
  • Page 53: Safety And Electromagnetic Compatibility Certifications

    Safety and Electromagnetic Compatibility Certifications Emission: Immunity: Safety: AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Class A, FCC Part 15Class A, C-TICK EN55024 EN60950, UL60950, FCC Part 68...
  • Page 54: Translated Electrical Safety And Emission Information

    Appendix C Translated Electrical Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
  • Page 55 Operating Temperature: temperature of 40 degrees C. Install product in accordance with local and National Electrical Codes. All Countries: AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Class A, FCC Part 15 Class A, C-TICK EN55024 EN60950, UL60950, FCC Part 68...
  • Page 56 Betriebstemperatur: Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40° C entworfen. Alle Länder: Installation muß örtlichen und nationalen elektrischen Vorschriften entsprechen. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Klasse A, FCC Part 15 Klasse A, C-TICK EN55024...
  • Page 57 Betjeningstemperatur: Dette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C. Alle Lande: Installation af produktet skal ske i overensstemmelse med lokal og national lovgivning for elektriske installationer. AT-MC601 and AT-MC602 Installation and User’s Guide C-TICK EN55024 EN60950, UL60950, FCC Part 68...
  • Page 58 Bedrijfstemperatuur: De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius. Alle Landen: het toestel installeren overeenkomstig de lokale en nationale elektrische voorschriften. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Klasse A, FCC Part 15 Klasse A, C-TICK EN55024...
  • Page 59 Température De Fonctionnement: Ce matériel est capable de tolérer une température ambiante maximum de 40 degrés Celsius. Pour Tous Pays: Installer le matériel conformément aux normes électriques nationales et locales. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Classe A, FCC Part 15 Classe A, C-TICK EN55024...
  • Page 60 Käyttölämpötila: Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40° C. Kaikki Maat: Asenna tuote paikallisten ja kansallisten sähköturvallisuusmääräysten mukaisesti. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Luokka A, FCC Part 15 Luokka A, C-TICK EN55024 EN60950, UL60950, FCC Part 68...
  • Page 61 Temperatura Di Funzionamento: Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi centigradi. Tutti I Paesi: installare il prodotto in conformità delle vigenti normative elettriche nazionali. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Classe A, FCC Part 15 Classe A, C-TICK EN55024...
  • Page 62 Driftstemperatur: Dette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader celsius. Alle Land: Produktet må installeres i samsvar med de lokale og nasjonale elektriske koder. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Klasse A, FCC Part 15 Klasse A, C-TICK EN55024...
  • Page 63 40 graus centígrados. Todos Os Países: Instale o produto de acordo com as normas nacionais e locais para instalações elétricas. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Classe A, FCC Part 15 Classe A, C-TICK...
  • Page 64 40 grados C. Para Todos Los Países: Monte el producto de acuerdo con los Códigos Eléctricos locales y nacionales. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Clase A, FCC Part 15 Clase A, C-TICK...
  • Page 65 Driftstemperatur: Denna produkt är konstruerad för rumstemperatur ej överstigande 40 grader Celsius. Alla Länder: Installera produkten i enlighet med lokala och statliga bestämmelser för elektrisk utrustning. AT-MC601 and AT-MC602 Installation and User’s Guide EN55022 Klass A, FCC Part 15 Klass A, C-TICK EN55024...