Led Status; Transmitter; Receiver - Thinklogical DCS StudioPRO Product Manual

Usb and video extender
Table of Contents

Advertisement

3.4.

LED Status

3.4.1. Transmitter

LED Label
DDC Pass
DDC Dynamic
DDC Static
Power
USB Link
Host

3.4.2. Receiver

LED Label
USB 1,2,3,4
Video
(Single-Link Version Only)
Video SL
(Dual-Link Version Only)
Video DL
(Dual-Link Version Only)
DDC Pass
DDC Dynamic
DDC Static
Power
USB Link
MAN-000018
Status
LED is ON (solid green) for DDC Pass thru mode. In this mode, the CPU
communicates directly with the connected monitor for DDC information.
LED is ON (solid green) for DDC Dynamic mode. In this mode, the DDC of
the monitor is read from the receiver and stored in the transmitter.
LED is ON (solid green) for DDC Static mode. In this mode the DDC
information in the transmitter is not changed regardless of changes made
at the receiver end.
LED is ON (solid green) when power is connected
Shows the status of the connection
LED is ON (solid green) when the Power, device port(s), and Fibers are
properly connected
LED is BLINKING (blinking green) when the Fibers are properly connected
and until the Host enumerates
LED is ON (solid green) when the computer establishes a USB connection.
Status
LED is ON (solid green) when a device is connected to the
corresponding USB device port.
LED is ON (solid green) when a DVI signal is properly established.
LED is ON (solid green) when a Single-Link DVI signal is properly
established.
LED is ON (solid green) when a Dual-Link DVI signal is properly
established.
LED is ON (solid green) for DDC Pass thru mode. In this mode, the
CPU communicates directly with the connected monitor for DDC
information.
LED is ON (solid green) for DDC Dynamic mode. In this mode, the
DDC of the monitor is read from the receiver and stored in the
transmitter.
LED is ON (solid green) for DDC Static mode. In this mode the DDC
information in the transmitter is not changed regardless of changes
made at the receiver end.
LED is ON (solid green) when power is connected
Shows the status of the connection
LED is ON (solid green) when the Power, device port(s), and Fiber are
properly connected
LED is BLINKING (blinking green) when the Fiber are properly
connected and until the Host enumerates
12
REVISION A

Advertisement

Table of Contents
loading

Table of Contents