Oil Pump Servicing; Introduction - Stanley Alpha 120 Servicing Instructions

Twin burner, oil fired central heating range cooker
Table of Contents

Advertisement

SEE FIG. 14

INTRODUCTION

To carry out servicing on the oil pump. Turn off the oil line
isolating valve near to the appliance.
OIL PUMP STRAINER CLEANING
SEE FIG. 18
1. Remove 4 socket head screws
2. Remove filter.
3. Wash with clean petrol or paraffin.
4. Re-assemble in reverse order.
OIL LINE FILTER CLEANING
1. Turn OFF the line isolating valve fitted prior to the oil
line filter.
2. Follow manufacturers instructions to remove filter
element from the housing, taking care to collect
kerosene residue from the filter housing.
3. Wash filter thoroughly in clean petrol or paraffin.
4. Re-assemble in reverse order.
NOTE: Flexible fuel hose (s) must be replaced every 2
years.
STRAINER
COVER
FIG. 18
12

Oil Pump Servicing

SEAL
FUEL INLET
DESN 512002