Removing The Power Cord And Capacitor-Models Acq058Mm & Acq062Mm - Whirlpool ACM052MM Service Manual

2003 5000 & 6000 btu
Table of Contents

Advertisement

REMOVING THE POWER CORD AND CAPACITOR
MODELS ACQ058MM & ACQ062MM
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug air conditioner or disconnect power.
2.
Remove the air conditioner from the win-
dow.
3.
Remove the side curtains and the front
grille (see page 3-2 for the procedures).
4.
Remove the two power cord green ground
wire screws from the evaporator frame.
Power Cord Ground Wire Screws
5.
Remove the electronic control assembly
from the housing (see steps 5 and 6 on page
3-5 for the procedure).
6.
Disconnect the smooth power cord lead con-
nector from electronic control board termi-
nal L1.
Smooth Power Cord Lead At Terminal L1
7.
Remove the three screws from the control
housing and and remove the housing.
8.
Remove the two screws from the capaci-
tor cover, pull the cover forward, and re-
move it.
3-8
Screw 1 of 3)
Control Housing
Screws
Capacitor Cover

Hide quick links: