Whirlpool ACM052MM Service Manual page 27

2003 5000 & 6000 btu
Table of Contents

Advertisement

Electrical Shock Hazard
Connect green ground wires to ground
screws.
Failure to do so can result in death or
electrical shock.
Perform the following steps to reinstall the fan
motor.
1.
Mount the evaporator fan to the fan motor.
Keep the end of the fan approximately
1/4" from the end of the motor shaft.
2.
Slide the fan shroud and the condenser
fan blade and its clamp over the fan motor
shaft. Mount the clamp over the fan, but do
not tighten it at this time.
3.
Depending on the model, reconnect the
fan motor wires as follows:
a) Model ACD052: Black and red wires to
the fan speed control.
b) Models ACM052 & ACM062: Red,
black, and blue wires to the fan speed
control.
c) Models ACQ058 & ACQ062: Red,
black, and blue wires to the electronic
control board.
4.
Reconnect the brown and white wires to
the capacitor terminals.
Brown
All White Wires
& Power Cord
Lead (Ribbed)
To These Terminals
5.
Slide the lower styrofoam shield over the
evaporator fan.
N/C
H
N/C
F
C
Brown
F = Fan
C = Common
H = Compressor
6.
Carefully lift the fan motor assembly, the
condenser fan shroud, and the lower styro-
foam air shield, and install them in the unit.
7.
Rotate the fan motor so that the wires face
down toward the bottom of the unit.
8.
Mount the fan motor clamp over the end of
the motor with its two screws.
9.
Mount the condenser fan shroud with its
two hex-head screws.
10. Install the two upper styrofoam air shields
over the evaporator.
11. Make sure that the rubber wire block is
positioned in its cutout so that there are no
air leaks around it (see the photo in step 4
on page 3-16).
12. Mount the top air guide to the unit with its
eight screws.
13. Mount the brace to the top air guide and the
condenser fan shroud with its four screws.
14. Rotate the fans and make sure that the
condenser fan blade is not rubbing on the
shroud. If it does, push it back until it is
clear, and then tighten the clamp screw.
15. Mount the control housing with its three
screws.
16. Mount the control mounting plate/elec-
tronic control box to the housing.
17. Mount the green ground wires to the evapo-
rator with the hex-head screw.
3-13
Motor Wires Down