8.
Remove the two screws from the capaci-
tor cover, pull the cover forward, and re-
move it.
9.
To remove the power cord, disconnect
the ribbed lead from the capacitor termi-
nal.
10. To remove the capacitor:
a) Use a 20,000 Ω, 2-watt resistor and
discharge the capacitor. Touch the
resistor leads to terminals C & H and
C & F.
b) Disconnect the wires from the termi-
nals, and remove the capacitor.
Capacitor
Screws
Capacitor Cover
Ribbed Power Cord Lead
Electrical Shock Hazard
Connect green ground wires to ground
screws.
Failure to do so can result in death or
electrical shock.
Perform the following steps to reinstall the
capacitor and power cord:
1.
Reconnect the wires to the capacitor ter-
minals (see below) and reinstall the ca-
pacitor.
Brown
White
Power Cord
Lead (Ribbed)
N/C
White
2.
Reinstall the capacitor cover with its two
screws.
3.
Mount the control housing with its three
screws.
4.
Connect the smooth power cord lead to
fan speed control terminal 1.
5.
Mount the control mounting plate to the
control housing with its four screws.
6.
Connect the green ground wires to the
control mounting plate and the evaporator
frame with the two hex-head screws.
3-7
N/C
H
N/C
F
C
Brown
F = Fan
C = Common
H = Compressor