Machine Id; Variflex - Cino eC Pro Installation And Maintenance Manual

Table of Contents

Advertisement

cino eC PRO by
09.01.s. product audit
flux
09.01.t. machine id.
09.01.u. variflex
09.02. "data"
09.03. "test vend"
09.04. "clean"
09.05. "maintenance"
09.06. data support
MAN1010119 rel. 01 dated 30.01.2014
www.rheavendors.com
for every soluble canister can be set the delivered grams' quantity
by second (key "4" and "5");
display the partial and the total quantity of delivered product; the
partial audit can be erased by pressing the key "4" for some
seconds;
identification codes for data acquisition in EVA DTS:
- machine number;
- location number;
- machine configuration;
- address for the connection with the DDCMP protocol;
- 0 for the audit via telemetry; 1 to enable the IRDA acquisition; 2
to disable the acquisition;
to set the diameter of the coffee brewer installed in the machine;
it decides whether to keep the percolation chamber of the coffee
brewer inserted in the upper piston or not in the standby phase
(close);
to enable the grinder calibration time;
choose the option "data" to enable the display to show the data of
the dispensing cycles you have performed in succession, just as in
09.01.h.;
to dispense selections on a free basis; the selections made in this
mode are counted separately (see 09.01.h.);
choose this option and press "1=pb", "2=mx1", "4=water" or
"8=hc." to enable the vending machine to dispense a pre-fixed
water quantity to wash the corresponding circuit (see 08.03.);
to carry out the same functions as those described by point
09.01.o.;
the values of the variables composing the machine programming
(configuration) can be transferred to an external support, i.e. the
flash key; to transfer the machine parameters to the key:
- power off the machine;
- open the door;
- insert
the
flash
key
05.15. and 05.37.c);
- power on the machine with the service key (see 05.13.);
- the display shows:
- press "2";
- and wait for the display to show:
- power off the machine and remove the flash key;
now, the flash key contains all the parameters typical of the
machine from which they have been fetched. If you wish to
programme another vending machine with these data, the previous
procedure can be repeated by pressing key "1" instead of "2": the
information will be transferred from the flash key to the vending
machine; both procedures will not alter the data contained in the
supports from which they have been fetched;
tel: 0039 02 966 551
rheavendors group's sole property
into
the
orange
carter
fax: 0039 02 96 55 086
e mail: rheavendors@rheavendors.com
calibr. motor N
gr/sec
product
N
Parz. g.
product
N
Tot. g.
code ID 101
code ID 104
code ID 106
address VIDTS
Data Audit 0=TLMS
1=IRDA 2=off 00
BREWER DIAMETER
0=36 1=45
POSIT. STAND BY
0=close 1=open 00
Autom. Adjustment
f. Tuning 1=yes 0
TEST VEND
CLEANING
butt: 1=pb 2=mx1
4=water
slot
(see
1 from key to VMC
2 from VMC to key
END PROGRAMMING
wait .........
page no. 36 of 52 page
used
00
used
00
00
00
00
00
00
8=hc.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents