Wire The Control Panel - Bosch Easy Series ICP-EZM2 Quick Start Manual

Hide thumbs Also See for Easy Series ICP-EZM2:
Table of Contents

Advertisement

6
en | Wire the Control Panel
2

Wire the Control Panel

Refer to Figure 2.1 for an overview of the system components and wiring.
1
2
RFRC-OPT
3
4
Figure 2.1: Wiring diagram
Callout
1
2
3
2014.09 | 01 | F.01U.306.216
IUI-EZ1
+
-
R
Y
G
B
R
Y
G
B
DX2010
R
Y
G
B
B426
R
Y
G
B
5
B450
R
Y
G
B
Description
Control Center
RADION receiver
DX2010 Point
Expander
(+) (-)
6
10
7
8
Quick Start Guide
Easy Series Control Panel
(+)
(-)
(-)
+
(+)
9
(+)
(+)
(-)
(+) (-)
(+) (-)
(+) (-)
(+) (-)
Mount within 3 m of control panel, Use
CAT5 cable (twisted pair) for audio
bus, Set data bus address (1 - 4), up to
4 controls max
1 = Normal Operation
5 = Maintenance Mode
Data bus Adr 102: Points 9-16
Data bus Adr 103: Points 17-24
Data Bus Adr 104: Points 25-32
Bosch Security Systems, Inc.
11