Easy Series Control Panel
System Programming Items
Item
No.
163
164
165
166
167
168
601
Audio Verification Commands
SIA Standard Audio Verification Commands (Item No. 168 = 0)
Phone Button
[1]
[3]
[6]
[7]
[9][8]
[9][9]
[0]
[#]
Bosch Security Systems, Inc.
Programming Item
Silence Trouble Tones 0 = All trouble tones beep at the control
System Inactivity Time
(Hours)
System Inactivity Time
(Days)
System Inactivity Time
(Weeks)
Force Arm/Exit Error
Audio Verification
Command Set
Enable Keyfob Duress
Quick Start Guide
Range
center.
1 = Only Fire and 24-Hour trouble tones
beep at the control center.
Enter the number of hours (0-255) that the
system must be off before it sends the
System Inactive report.
Enter the number of days (0-255) that the
system must be off before it sends the
System Inactive report.
Enter the number of weeks (0-255) that the
system must be off before it sends the
System Inactive report.
0 = Off-normal points create an exit error at
the end of Exit Delay
1 = Off-normal points are force-armed at the
end of Exit Delay
0 = Use SIA Standard Audio Verification
commands (AV-01-1997.11)
1 = Use alternate audio verification
command set
0 = Wireless keyfob does not send a Duress
event
1 = Wireless keyfob sends a Duress event
Command
Talk to premises.
Listen to premises.
Listen to premises.
Restart 90-second timer.
Terminate session with call back.
Terminate session without call back.
Listen to all microphones.
Cancels first digit of command.