Bosch Easy Series ICP-EZM2 Quick Start Manual page 15

Hide thumbs Also See for Easy Series ICP-EZM2:
Table of Contents

Advertisement

Easy Series Control Panel
System Programming Items
Item
No.
163
164
165
166
167
168
601
Audio Verification Commands
SIA Standard Audio Verification Commands (Item No. 168 = 0)
Phone Button
[1]
[3]
[6]
[7]
[9][8]
[9][9]
[0]
[#]
Bosch Security Systems, Inc.
Programming Item
Silence Trouble Tones 0 = All trouble tones beep at the control
System Inactivity Time
(Hours)
System Inactivity Time
(Days)
System Inactivity Time
(Weeks)
Force Arm/Exit Error
Audio Verification
Command Set
Enable Keyfob Duress
Quick Start Guide
Range
center.
1 = Only Fire and 24-Hour trouble tones
beep at the control center.
Enter the number of hours (0-255) that the
system must be off before it sends the
System Inactive report.
Enter the number of days (0-255) that the
system must be off before it sends the
System Inactive report.
Enter the number of weeks (0-255) that the
system must be off before it sends the
System Inactive report.
0 = Off-normal points create an exit error at
the end of Exit Delay
1 = Off-normal points are force-armed at the
end of Exit Delay
0 = Use SIA Standard Audio Verification
commands (AV-01-1997.11)
1 = Use alternate audio verification
command set
0 = Wireless keyfob does not send a Duress
event
1 = Wireless keyfob sends a Duress event
Command
Talk to premises.
Listen to premises.
Listen to premises.
Restart 90-second timer.
Terminate session with call back.
Terminate session without call back.
Listen to all microphones.
Cancels first digit of command.
Appendix | en
15
2014.09 | 01 | F.01U.306.216