Control unit for a 24 vdc motor, for a sliding gate, up-and-over door or barrier

Advertisement

EN
PARAMETS
0 = deactivated
1 = gate open light ON/OFF
2 = gate open light proportional
- Slow lashing with gate opening
- Quick lashing with gate closing
- Steady light if gate open
IN.D.
- 2 lashes + pause with gate stationary (position other than
15
closed)
3 = Electric lock
4 = Magnetic electric lock function with output active when
gate/door is closed
N.B. interface with an external relay with 24 Vdc winding. To
activate this function, the pre-lash must be enabled at the
recommended value of 1 sec (tP.r. ≠ 0)
se.r.
Service interval cycle threshold.
16
(0 = off)
Enabling of continuous lashing indicating
service required with se.r. ≠ 0 (only active with gate
se.f.
closed).
17
0 = off
1 = on
EL.T.
Electric lock activation time in seconds
18
ST.P.
High-speed motor start-up.
19
0 = on
1 = off
EN.C.
1 = Off (use of virtual encoder)
20
2 = On (use of motor's physical encoder)
NE.P.
1 to 10 pulses per revolution of the physical encoder
21
0 = deactivated
1 = Restore of factory settings for sliding gate motor
SUN4224, SC4224
DE.F.
2 = Restore of factory settings for sliding gate motor
SUN7224, SC7224
22
3 = Restore of factory settings for sliding gate motor
SUN11224, SC11224
4 = Restore of factory settings for barrier and up-and-over
door
28
DESCRIPTION
DEFAULT
MIN
MAX
0
0
4
10
0
200
0
0
1
4
1
10
0
0
1
1
1
2
4
1
10
0
0
4
UNITA'
TIPO
SL/BA/
OH
x 1000
SL/BA/
cycles
OH
SL/BA/
OH
SL/BA/
s
OH
SL/BA/
OH
SL/BA/
OH
SL/BA/
OH
SL/BA/
OH