Building Technologies
Fire Safety & Security Products
Alarm Input
ON: Detects an external alarm.
OFF: Does not perform alarm detection.
Digital Input
Alarm Input: Detects an external alarm.
Mode
OFF: Does not perform alarm detection.
B/W Mode: Sets the camera into monochrome mode if a trigger signal
is received. (This function is available for CCDS1315-LP only)
Input Type
NO (Normally Opened): An alarm will be triggered when the external
contact closes.
NC (Normally Closed): An alarm will be triggered when the external
contact opens.
Text Enable
Define whether an alarm text will be overlaid on the video image.
Text
Define a text for the alarm message. Max. 24 characters can be
entered.
Audio Output
When set to ON, an audio alarm message can be sent to an external
speaker.
NOTE: A speaker with integrated amplifier must be connected to the
AUDIO out jack on the rear panel.
Event
Select the pre-recorded sound file (on the SD card) to be output as a
sound alarm. See page [
39] .
CCMx1315-LP Configuration Manual EN
Configuration
37
05.05.2009