v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3200 Types 4362 and 4363," on page 27 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System-error log message
Flash of x by y via z was successful...w
Flash of x via z failed for user z...z
Flash succeeded for x (address: y)
Hard Drive x Fault
Hard drive x removal detected.
Internal Error CPU Fault
Invalid userid or password received. Userid is w,
x, y, z
LAN: Command Mode tamper triggered.
Possible break in attempt
LAN: Telnet tamper triggered. Possible break in
attempt
LAN: Web Server tamper delay triggered.
Possible break in attempt
LAN: Ethernet interface is no longer active
LAN: Ethernet interface is now active
No ISMP Gateway defined for the interconnect
network. RSA x is Assuming the Gateway
OS Watchdog response disabled by x
OS Watchdog response enabled by x
PFA Alert, see preceding error in system error
log
Possible ASM reset occurred -- reason unknown Information only.
Power off
Power on
PPP[xxx] PPP-Cfg, Local-
IP@=aaa.aaa.aaa.aaa, Remote-
IP@=bbb.bbb.bbb.bbb NetMsk=ccc.ccc.ccc.ccc,
Auth=ddd
PPP_1:Client Connected at xxx bps
PPP_1:User requested to abort PPP interface
140
System x3200 Types 4362 and 4363: Problem Determination and Service Guide
Action
Information only.
Information only.
Information only.
1. Run the diagnostics programs.
2. Replace hard disk drive x.
3. Replace the following component, depending on the server
model:
v Hot-swap models: Hard disk drive backplane
v Simple-swap models: Hard disk drive x cable
Reseat the following component, depending on the server model:
v Hot-swap and simple-swap models: Hard disk drive x
Information only. If the message remains:
1. (Trained service technician only) Reseat the microprocessor.
2. (Trained service technician only) Replace the microprocessor.
Information only.
Information only.
Information only.
Information only.
Information only.
Information only.
Information only.
Information only.
Information only.
Information only. See the preceding entry in the system-error log.
Information only.
Information only.
Information only.
Information only.
Information only.