Activating/deactivating local voice messages

6.4
If a particular event such as a panic alarm or a fire occurs, the ABUS wireless alarm
system informs the occupants of the object about the current status. It does this by
playing a local voice message. You can activate or deactivate voice messages according
to the event. In the default factory setting, all voice messages are activated.
To activate/deactivate voice messages:
1.
Under user functions, press [7] for Voice Messages.
2.
Enter your user PIN and press
3.
Select [4] for Local Announcement Messages. You see a list of system
events.
4.
From this list of system events, select the events for which you want to
activate/deactivate voice messages:
[1] Intruder alarm,
[4] Panic alarm,
[6] Stay arming,
[8] Disarming,
[10] Entry delay,
[12] Trouble messages, [13] Walk test
5.
Press
[N]: The voice message is deactivated for the selected event.
[Y]: The voice message is activated for the selected event.

Local message

6.5
Your ABUS wireless alarm system can record a local voice message up to 8 seconds
long. You can play the message locally over the loudspeakers of the ABUS wireless
alarm system. When you record a new message, the old message is deleted.
To record a message:
1.
Press
slowly.
2.
After the acoustic signal, speak your message at a short distance into the
microphone of the ABUS wireless alarm system. The microphone is in the bottom
left corner of the panel. When you are finished, press
LED now flashes fast.
To play back a message:
Press
: the recorded message is played back.
[2] Fire alarm,
[5] Away arming
[7] Auto arm/disarm
[9] Exit delay
[11] Functions Key messages
to select between the following options:
and keep it pressed for 2 seconds. The MESSAGE LED flashes
.
[3] Emergency alarm
again. The MESSAGE
37