Amana AXP Series Service Training Manual page 58

High speed combination oven
Table of Contents

Advertisement

1. At the end of a cook cycle and the food is removed and the door is closed the display indicates.
2. When a pad is pressed the display indicates.
OVEN NOT AT
OVEN NOT AT
PREHEAT
PREHEAT
TEMPERATURE
CLEAN
CLEAN
FILTER
FILTER
CHECK DOOR
RESTART
PROGRAM
CHASSIS
MEMORY
ERROR
OPERATIONAL CODES
1. Normal do not service the oven for this.
Change Option Code #10 to OFF
Option #12 This is activated at the factory.
It will appear every 7 days.
Note: Customer can change this option
as desired. See Quick Start Reference
Guide section.
See component test procedures section
for testing procedures and results.
1. Door not fully closed.
2. Inoperative Power Relay.
3. Inoperative Primary Interlock Switch.
4. Inoperative Secondary Interlock Switch.
5. Secondary Interlock Switch out of Adjustment.
6. Broken or Loose Wire Connection.
7. Inoperative HV System (Magnetron).
1. Unplug the oven and remove right side panel.
2. Disconnect the data key board connector
from the display board (Figure 1).
3. Plug the oven in (See Caution below).
4. Carefully reinstall data keyboard connector
onto the display board.
5. Press and hold Pad 2 ( The display will
indicate user options).
6. Press Save pad.
Note: If chassis memory error returns replace
data keyboard.
CAUT IO N