Advertisement

Antenna Motor
Screen
RTD Status
Screen
This screen will allow operation of the
antenna motor show the number of amps
being drawn.
NEXT TEST: Press this pad to go to the
next Service Mode Test
0
PREV TEST: Press this pad to go to the
previous Service Mode Test
TURN ON: This pad will toggle between
turning the antenna motor on and off.
CANCEL: Press this pad to return to the
Main Menu
RANGE: Under normal operation, the amp
draw may be to low to read.
This screen will show the temperatures
being reported to the RTD's in the oven.
The maximum temps seen by the controller
are also recorded for diagnostic purposes.
NEXT TEST: Press this pad to go to the
next Service Mode Test
PREV TEST: Press this pad to go to the
previous Service Mode Test
CANCEL: Press this pad to return to the
Main Menu
CLEAR INFO: Press this pad to reset the
Maximum RTD temps to zero.