  • Page 1 SAFETY AND OPERATING MANUAL ROUTER SF1500XP...
  • Page 3 - Repairs attempted by anyone, unless authorized by Screwfix Direct Ltd. This guarantee does not affect your statutory rights.This guarantee is only valid in the UK. For further technical advice, spare parts or repair service (outside of guarantee) please contact the customer helpline number on 0845 607 6380. ROUTER SF1500XP...
  • Page 4: Safety Instructions

    SAFETY INSTRUCTIONS WARNING! Read all instructions.Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. SAVETHESE INSTRUCTIONS 1. Work area. a. Keep work area clean and well lit. Cluttered and dark areas invite accidents. b.
  • Page 5 (e.g. lead from old gloss paint). You are advised to consider the risks associated with the materials you are working with and to reduce the risk of exposure.You should: - Work in a well-ventilated area. ROUTER SF1500XP...
  • Page 6: Double Insulation

    - Work with approved safety equipment, such as those dust masks that are specially designed to filter microscopic particles. ADDITIONAL SAFETY INSTRUCTIONS FOR YOUR ROUTERS 1.Sawdust and splinters must not be removed while the machine is running. 2.Protect router bits against shocks and impacts. 3.Only use properly sharpened router bits, otherwise increased cutting force will shatter the workpiece.
  • Page 7 SYMBOLS Read the manual Warning Wear dust mask,eye & ear protection Wear gloves Conforms to relevant safety standards ROUTER SF1500XP...
  • Page 8 1. LOCK OFF BUTTON 2. ON/OFF TRIGGER SWITCH 3. HANDLE 4. DEPTH STOP BAR FIXING SCREW 5. DEPTH STOP BAR 6. TRIPLE DEPTH STOP 7. SPINDLE LOCK 8. COLLET NUT 9. ROUTING BASE 10. PARALLEL GUIDE LOCKING KNOB 11. PLUNGE LOCK LEVER 12.
  • Page 9: Technical Data

    NOISE AND VIBRATION DATA Sound pressure level: 94.1dB (A) Sound power level: 105.1dB (A) Vibration level: <1.14m/sec ACCESSORIES Router bits 15pcs Parallel guide Centering pin 1/4” Collet 1/2” Collet 8mm Collet 30mm Guide bush Spanner Vacuum adaptor Depth stop bar ROUTER SF1500XP...
  • Page 10: Operation Instructions

    OPERATION INSTRUCTIONS WARNING! Before using this tool, make sure you read the instructions carefully. Operating the router. Note: Make sure to disconnect the router from mains supply before fixing any accessories. Your router comes with the depth stop bar not assembled.
  • Page 11 Turn the appropriate screw with a screwdriver to obtain fine adjustment.(see fig9) Note all three screws can be adjusted, enabling you to make different depth cuts on the same Fig 8 ROUTER SF1500XP...
  • Page 12 workpiece. If you wish to make a deep cut it is best to do this in 2 or 3 stages.The triple depth stop, can be used for this purpose by making small variations in the 3 positions available. 6. VARIABLE SPEED CONTROL SWITCH (see fig10) The variable speed control switch allows you to vary the speed of the router enabling the optimum...
  • Page 13 fig20) Use this attachment to cut out a shape using a pre formed template (ie a worktop jig). Fix the Guide Bush to the router base using the two long screws provided. Thereafter use the instructions Fig 16 ROUTER SF1500XP...
  • Page 14: Router Bits

    provided by the template manufacturer. 12. CHANGING THE ROUTER BIT Press the spindle lock and get the spindle to latch in place. Loosen the collet nut with the open- ended spanner. Change the router bit and tighten the collet nut with the spanner. Note: Remove all adjustment and assembly tools before starting the machine.
  • Page 15 Tools and tool bodies shall be clamped in such a way that they shall not become loose during operation. Care shall be taken when mounting tools to ensure ROUTER SF1500XP...
  • Page 16 that the clamping is by the hub of the tool and that the cutting edges are not in contact with each other or with the clamping elements. Fastening screws and nuts shall be tightened using the appropriate spanners, etc., and to the torque value provided by the manufacturer.
  • Page 17 The cutter of your router rotates clockwise. For more efficient cutting, move your router from left to right as you stand facing the workpiece. Note: When cutting outside edges, move your router anticlockwise and clockwise when cutting inside edges. ROUTER SF1500XP...
  • Page 18: Maintenance

    MAINTENANCE 1.Your power tool requires no additional lubrication or maintenance.There are no user serviceable parts in your power tool. 2. Never use water or chemical cleaners to clean your power tool. Wipe clean with a dry cloth. 3. Always store your power tool in a dry place. 4.
  • Page 19 L. A 13AMP (BS1363 or BS1363/A) plug must be used and a 13 AMP fuse must be fitted. 13 AMP FUSE BLUE N (NEUTRAL) BROWN L (LIVE) OUTER CABLE GRIP SLEEVE ROUTER SF1500XP...
  • Page 20: Declaration Of Conformity

    Houndstone Business Park Yeovil BA 22 8RT Declare that the product ½” ROUTER SF1500XP Complies with the essential health and safety requirements of the following directives: 89/336/EEC, 93/68/EEC – EMC Directive. 73/23/EEC, 93/68/EEC – Low Voltage Directive. 98/37/EC – Machinery Directive.