Adjusting the
Scan Heads
for Ladder
Orientation
Marks
(continued)
SV61611 Rev. B
8. Use the blue thumbwheel to move the Scan Head.
Figure 8.1: Use the Blue Thumbwheel to
Adjust Scan Head Position
Move the thumbwheel until the pointer lines up with the measurement
(distance from the center of the page to the center of the mark) defined
in Step 7.
Figure 8.2: Use the Pointer to Ensure Correct
Scan Head Position
9. If additional Scan Heads are to be used, repeat step 1 to 8 for each.
10. To verify the adjustment is correct:
a. From the home screen, select "Loading Instructions and Pre-Run
Adjustments" then "Scanner Setup".
b. Use the UP/DOWN arrow keys to select a feeder to run.
c. Press TRIAL PIECE to feed a piece from the highlighted feeder.
d. Select "Finish" when done.