Exit Options; Mailing System Interface (Dp800I Or Dp1000 Only) - Secap SI5400 Operator's Manual

Document inserting system
Table of Contents

Advertisement

Exit Options

Mailing System
Interface (DP800i
or DP1000 only)
SV61611 Rev. B
The exit portion of the system accepts a variety of options. The Letter Drop
Stacker and the Flats Drop Stacker are standard options for all systems.
The Mail Machine Interface (MMI) enables communication between the in-
serter and the DP800i or DP1000 mailing systems via a USB connection.
The inserter sends start and stop signals to the mailing system, and the
mailing system can send error messages back to the inserter to stop feed-
ing.
When the inserter starts the mailing system, it will toggle the Sealer to
"Off" and take control of the timeouts.
The inserter monitors the number of pieces exiting the DP800i or
DP1000 in order to prevent the mailing system from being overloaded
with mail.
If the mailing system is overcome with mail, the inserter will pause until
the mailing system can process the mail and will then resume.
When the mailing system is in maintenance mode, the inserter will
pause until the maintenance is complete.
If you want to operate the mailing system in standalone mode, press the
Stop key on the IntelliLink
ing any mail pieces in process. Press Start (at the mailing system) to
finish processing any pieces of mail on the feeder. Then, refer to your
the operating guide for you mailing system for instructions on processing
mail.
NOTE: Once you have completed processing mail in standalone mode, press
the Stop key. To resume using the MMI Interface, start the inserter.
Running the Mail Machine Interface
Follow the steps below to process mail using the MMI.
1. Power-up the inserting system.
2. Power-up the mailing system.
3. Ensure that the inserting system has been set up for the job:
The job must be loaded.
NOTE: The job must have "Use Postage Meter" option set to "On" for the
MMI to function. Refer to Creatng a Job in Chapter 3 for more informa-
tion.
The material must be loaded.
A trial piece must be run successfully.
Add-On Modules • 7
Control Center. The inserter will finish creat-
®