Resetting Memory; Selecting Arc Start/Volt Sense Error Shutdown - Miller Auto Invision II Owner's Manual

Automatic welding interface and arc welding power source
Table of Contents

Advertisement

10-12. Resetting Memory

Press Mode
Access
Select
Setup
Display
5
> Process
Sequence
SharpArc
Card

10-13. Selecting Arc Start/Volt Sense Error Shutdown

Access
Setup
Display
Press Mode
Select
Display
Memory
> Shutdown
Name
OM-201 396 Page 60
Wiretype
Display
> Memory
Shutdown
Parameter
Select
> Prg 1
Pulse
035" Steel
Argon – Oxy
Parameter
Select
Parameter
Select
1
Arc Start/
Volt Sense
> On
> No Reset
Increase/
Decrease
> Program 1
Reset
Press
Increase/
Decrease
> System
Reset
Press
Increase/
Decrease
> Total
Reset
Press
Increase
Arc Start/
Volt Sense
> Off
1
No Reset
Press Parameter Select button to
exit memory reset parameter with-
1
out resetting any data.
2
Program Reset
Press Parameter Select button to
reset last active program to original
factory program settings. All other
program and setup information
remains the same. If setup card is in
card slot, program will be loaded
from card.
3
System Reset
Press Parameter Select button to
reset programs and setup to
original factory settings. System,
Arc Time, and Robot Control
settings are not affected by the
2
system reset. If setup card is in
card slot, program will be loaded
from card.
4
Total Reset
Press Parameter Select button to
reset programs and setup to origi-
nal factory settings for all programs
and setup including System and
Arc Time. If setup card is in card
3
slot, program will be loaded from
card.
5
Reset (Default) Displays
4
1
Voltage Shutdown Display
With Arc Start/Volt Sense on, the
unit shuts down when no arc
voltage is sensed. If the unit shuts
down, an error message appears
(see Section 12-6).
With Arc Start/Volt Sense off, the
unit continues to feed wire even
when there is no arc voltage
sensed.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents