Removing Case And Measuring Input Capacitor Voltage For 575 Volt Model - Miller Auto Invision II Owner's Manual

Automatic welding interface and arc welding power source
Table of Contents

Advertisement

12-4. Removing Case and Measuring Input Capacitor Voltage For 575 Volt Model

Tools Needed:
5/16 in
+ lead to lower right
terminal, – lead to
upper right terminal
Y Significant DC voltage can remain on capacitors af-
ter unit is Off. Always check the voltage as shown
to be sure the input capacitors have discharged be-
fore working on unit.
1
1
2
3
Turn Off welding power source, and
disconnect input power.
1
Outside Handle Screws
To loosen top, remove two outside
handle screws from both handles
and all side bolts.
2
Interconnect Board PC2
3
Voltmeter
Measure the dc voltage across the
screw terminals on PC2 as shown
until voltage drops to near 0 (zero)
volts.
Proceed with job inside unit. Rein-
stall cover when finished.
Ref. 801 914 / Ref. 801 917
OM-201 396 Page 71