2-3. Selecting A Location

Movement
Location
Y Special installation may be required where gasoline or volatile
liquids are present – see NEC Article 511 or CEC Section 20.
18 in
(460 mm)

2-4. Connection Diagram

2
1
11
OM-201 396 Page 10
2
OR
1
5
18 in
(460 mm)
3
4
13
12
10
Tipping
3
4
5
6
7
8
9
Y Do not move or operate
unit where it could tip.
1
Lifting Forks
Use lifting forks to move unit.
Extend forks beyond opposite side
of unit.
2
Lifting Handles
Use handles to lift unit.
3
Hand Cart
Use cart or similar device to move
unit.
4
Rating Label
Use rating label to determine input
power needs.
5
Line Disconnect Device
Locate unit near correct input
power supply.
loc_2 3/96 - 801 958 / 801 914
.
The proper interface kit must
be installed in the interface unit
to allow it to be connected to the
robot.
1
Robot (Will Vary According To
Application)
2
Motor/Drive Assembly
3
Gas Cylinder
4
Gas Hose
5
Robot Control
6
Robot Input/Output Cable
7
Remote Program Select
Cable (Optional)
8
Gas And Motor Control Cable
9
Welding Power
Source/Interface Unit
10 Negative (–) Weld Cable
11 Workpiece
12 Voltage Sensing Lead
.
Positive (+) voltage sensing
lead is contained in the motor
cable.
13 Positive (+) Weld Cable
801 915-A