Trouble Shooting - Mastervolt Sunmaster XS4300 User And Installation Manual

Grid connected solar inverter
Hide thumbs Also See for Sunmaster XS4300:
Table of Contents

Advertisement

TROUBLE SHOOTING

6 TROUBLE SHOOTING
Consult an installer, if you cannot solve the problem by means of the table below.
Error LED
Error Code
Off
NONE
Off
Off
Off
WAIT 0:00
Off
SOL1 LOW
Off
COUNTRY
(or any name of
a country)
On
TEMP HI
On
SOL1 HIGH
On
NO GRID
On
ENS OFF
On
G83 OFF
On
VAC LOW
On
VAC HIGH
On
FAC LOW
On
FAC HIGH
On
INSULATION
Fast blinking
NTC FAIL
Fast blinking
EF I2C FAIL
Fast blinking
ENS FAIL
Fast blinking
CB I2C FAIL
Fast blinking
HW VAC FAC
Fast blinking
HW RELAY
Fast blinking
HW ERROR 1-9
18
Meaning
No error
Insufficient irradiation
No power from the PV
modules
Start-up
Voltage of the Solar
input is low
(Text is blinking)
Country code has not
been selected yet
Internal temperature of
the inverter is high
Voltage of the Solar
input is high.
No connection to the
AC-grid
ENS fault
G83 fault
AC voltage low
AC voltage high
AC frequency low
AC frequency high
Insulation failure
Defective device in the
Sunmaster
What to do?
Nothing; the inverter is working normally
Nothing. Irradiation of the PV modules is insufficient (for
instance during night time)
Consult an installer if the display does not show any
information during daytime. The wiring between the PV
modules and the Sunmaster might be defective.
Nothing. After the Sunmaster was (re)connected to the AC
grid, it checks the quality of the AC grid before it starts
operating normally. This may take up to 5 minutes.
Nothing; normal condition during sunrise and sunset.
Consult an installer if the problem remains while irradiation of
the PV modules is sufficient.
Select the correct country code. See section 4.3.2.
Maybe the air flow of the Sunmaster is obstructed. See chapter
3.3 for installation guidelines. If the problem remains, consult
an installer
Contact your supplier.
Check the connection to the AC-grid. Check the fuse in the
meter cupboard.
Error created by a grid safety device. The grid quality is
outside normal limits. Check the grid connection (for instance
too thin or too long AC wiring). Consult an installer
Voltage of the AC grid is too low. Consult an installer.
Voltage of the AC grid is too high. Consult an installer.
Frequency of the AC grid is too low. Consult an installer.
Frequency of the AC grid is too high. Consult an installer.
Leak current between PV modules and grounding. Consult an
installer.
Write down the exact error text. Consult an installer for
replacement of the Sunmaster.
November 2008 / Sunmaster XS4300-3200-2000 / EN