Mastervolt Sunmaster XS4300 User And Installation Manual

Mastervolt Sunmaster XS4300 User And Installation Manual

Grid connected solar inverter
Hide thumbs Also See for Sunmaster XS4300:

Advertisement

USER'S AND INSTALLATION MANUAL / GEBRUIKERS- EN INSTALLATIEHANDLEIDING
BEDIENUNGS- UND INSTALLATIONSANLEITUNG / MANUEL UTILISATEURS ET D'INSTALLATION
MANUAL DEL USUARIO Y DE INSTALACIÓN / MANUALE DI USO E MANUTENZIONE
XS4300/ XS3200/ XS2000
MASTERVOLT
Snijdersbergweg 93,
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
Fax.: +31-20-6971006
www.mastervolt.com
Sunmaster
Grid connected solar inverter
ENGLISH:
NEDERLANDS:
DEUTSCH:
FRANÇAIS:
CASTELLANO:
ITALIANO:
Copyright © 2008 Mastervolt, v1.1 November 2008
PAGE 1
PAGINA 29
SEITE 53
PAGINA 77
PÁGINA 101
PÁGINA 125

Advertisement

Table of Contents
loading

Summary of Contents for Mastervolt Sunmaster XS4300

  • Page 1 Grid connected solar inverter ENGLISH: PAGE 1 MASTERVOLT NEDERLANDS: PAGINA 29 Snijdersbergweg 93, DEUTSCH: SEITE 53 1105 AN Amsterdam FRANÇAIS: PAGINA 77 The Netherlands CASTELLANO: PÁGINA 101 Tel.: +31-20-3422100 ITALIANO: PÁGINA 125 Fax.: +31-20-6971006 www.mastervolt.com Copyright © 2008 Mastervolt, v1.1 November 2008...
  • Page 2 Key S2: Source Key S1: Menu Error LED Key S4: Select Key S3: Info LCD display Figure 1: overview of the Mastervolt Sunmaster XS 4300/ 3200/2000. CONTENTS: v 1.1 November 2008 GENERAL INFORMATION.............................. 4 Product description............................. 4 Use of this manual.............................. 4 Validity of this manual ............................
  • Page 3: Table Of Contents

    SPECIFICATIONS ................................. 19 Technical specifications ........................... 19 Outline drawings............................... 21 ORDERING INFORMATION............................22 ITALY SELF TEST................................. 23 CERTIFICATES ................................26 10.1 Certificate of VDE-0126 conformity ........................26 10.2 EC declaration of conformity ..........................27 EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 4: General Information

    The warranty is limited to the costs of repair and/or photovoltaic modules. replacement of the product by Mastervolt only. Costs for Depending on the application and in order to meet the installation labour or shipping of the defective parts are not local applicable regulations, the Sunmaster can be covered by this warranty.
  • Page 5: Safety Guidelines And Warnings

    Use of the Sunmaster other than as mentioned under § 2.2 is not considered to be consistent with the intended purpose. Mastervolt is not liable for any damage resulting from the above. EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 6: Before You Start

    XS4300 IP44 ENS SW 131003200 XS3200 IP44 ENS 131013200 XS3200 IP44 ENS SW 131002000 XS2000 IP44 ENS 131012000 XS2000 IP44 ENS SW Table 1 WARNING Never use the Sunmaster for a non-intended application! November 2008 / Sunmaster XS4300-3200-2000 / EN...
  • Page 7 BEFORE YOU START 10 cm 10 cm 10 cm 10 cm Figure 3 Minimum 50 cm Figure 5 Figure 4 EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 8: Ac Wiring

    For example international standard IEC60364-7-712 prescribes a DC switch in solar electric installations in buildings. For this reason Mastervolt offers several models of the Sunmaster with integrated DC-switch. See chapter 3.2 to check if your Sunmaster is equipped with such a DC-switch.
  • Page 9: Connection Of Two Strings (Standard)

    PV-modules. See figure 9. String 1 String 2 String 1 + 2 String 3 + 4 MultiContact Y-adapters AC grid Figure 7 Figure 9 AC grid Figure 8: Y-adapter EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 10: General Safety And Installation Precautions

    • cabling and/or the terminal connections. RS485 communication cables. • Follow steps installation instructions in order of succession as described. • The DC switch, if installed, must stay in OFF-position during entire installation. November 2008 / Sunmaster XS4300-3200-2000 / EN...
  • Page 11: Installation

    Place the Sunmaster over the mounting bracket and then move it downwards until it is locked by the mounting bracket. Figure 12 Figure 15 EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 12: Use In Italy

    If connection has been made correctly and solar irradiation is sufficient, the Sunmaster will switch on automatically. Figure 17 This may take a few seconds. At first commissioning the country code must be selected. See section 4.3.2. November 2008 / Sunmaster XS4300-3200-2000 / EN...
  • Page 13: Country Code Selection

    If the correct country code is shown, press S2 to Disconnect the MultiContact connectors from the select Sunmaster. Remove the bottom plate of the Sunmaster and disconnect the AC wiring. Now the Sunmaster can be demounted in a safe way. EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 14: Operation

    This is a normal effect which has a positive contribution to the efficiency and lifetime of the Sunmaster. LCD Display S1: Menu S2: Source Error LED S3: Info S4: Select Figure 23: operation of the LCD-display November 2008 / Sunmaster XS4300-3200-2000 / EN...
  • Page 15: Actual Readings

    AC grid PV-string AC grid frequency Ω AC grid impedance* °C Internal temperature of Internal temperature of the inverter the inverter Energy generated today * ENS-models only (see chapter 3.2), else 0.00 is shown. EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 16: Historical Data

    One day back in the past. displayed. Press and hold Scrolling days forward. This value represents the total operating hours of the selected input. Examples: Shows today’s data Shows yesterday’s data Shows data from one week ago November 2008 / Sunmaster XS4300-3200-2000 / EN...
  • Page 17: System Information

    Display switches between the firmware of Sunmaster. Never use any liquids, acids and/or scourers. the inverter (“XS”) and the display (“DS”). ►ERROR In case of a system failure, the cause of the failure is displayed. See section 5.3.5. EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 18: Trouble Shooting

    Sunmaster replacement of the Sunmaster. Fast blinking EF I2C FAIL Fast blinking ENS FAIL Fast blinking CB I2C FAIL Fast blinking HW VAC FAC Fast blinking HW RELAY Fast blinking HW ERROR 1-9 November 2008 / Sunmaster XS4300-3200-2000 / EN...
  • Page 19: Specifications

    PG-13.5 gland and screw PG-13.5 gland and screw PG-13.5 gland and screw terminals 2.5 - 4 mm2 terminals 2.5 - 4 mm2 terminals 2.5 - 4 mm2 * Depending on country settings, see section 4.3.2 EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 20 2 galvanic isolated RS485 QS databus connections External communication 2 galvanic isolated MasterBus connections Monitoring (optional) QS Data Control Basic (PC Software). Free download from www.mastervolt.com Monitoring (optional) QS PC-Link (connect the QS-databus to the PC) Monitoring (optional) Data Control Premium II: datalogger for up to 6 inverters with local, remote or internet...
  • Page 21: Outline Drawings

    SPECIFICATIONS OUTLINE DRAWINGS 356 [14.0] 142 [5.59] 356 [14,00] 142 [5,61] Figure 30: Dimensions in mm (inch) of the Sunmaster XS4300, XS3200, XS2000 EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 22: Ordering Information

    Delivery includes: 100 meter modular cable, 100 pcs. modular jacks and crimping tool. Mastervolt can offer a wide range of products for both grid connected and independent autonomous electrical installations, See our website www.mastervolt.com for an extensive overview of all our products.
  • Page 23: Italy Self Test

    Automatically after test operation. The test accuracy is better than 1V/ 0.1Hz if ACTUAL DAY TOTAL SYSTEM grid voltage and frequency are stable. Menu FL-test Blinking ASTERVOLT ASTERVOLT Automatically after test Figure 31 Actual EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 24 ASTERVOLT ASTERVOLT Calculation by hand: UT = UG – (TIME * 11.5). FH-test Example: if UG = 230V and TIME = 4.00 s, Figure 33 UT = 230 - (4.00*11.5) = 184V. November 2008 / Sunmaster XS4300-3200-2000 / EN...
  • Page 25 Calculation by hand: FT = FG – (TIME * 0.05). Actual Example: if FG = 50.00 Hz and TIME = 6.00 s, Figure 35 the result is 50.00 - (6.00*0.05) = 49.70 Hz. EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 26: Certificates

    CERTIFICATES 10 CERTIFICATES 10.1 CERTIFICATE OF VDE-0126 CONFORMITY November 2008 / Sunmaster XS4300-3200-2000 / EN...
  • Page 27: Ec Declaration Of Conformity

    EN 61000-3-2, Dips, variations, flicker EN 61000-4-11 and -3-3 Immunity EN 55024 EN 61000-4-2 and -3 EN 61000-4-4, -4-5 and -4-6 LV directive 2006/95/EC Electrical safety EN 60950-1 Amsterdam, P.F. Kenninck, General Manager MASTERVOLT EN / Sunmaster XS4300-3200-2000 / November 2008...
  • Page 28 Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel : + 31-20-3422100 Fax : + 31-20-6971006 Email : info@mastervolt.com...